Literature DB >> 24030529

Leptin deficiency promotes central sleep apnea in patients with heart failure.

Ivan Cundrle1, Virend K Somers2, Prachi Singh2, Bruce D Johnson2, Christopher G Scott3, Christelle van der Walt2, Lyle J Olson4.   

Abstract

BACKGROUND: Leptin-deficient animals hyperventilate. Leptin expression by adipocytes is attenuated by atrial natriuretic peptide (ANP). Increased circulating natriuretic peptides (NPs) are associated with an increased risk of central sleep apnea (CSA). This study tested whether serum leptin concentration is inversely correlated to NP concentration and decreased in patients with heart failure (HF) and CSA.
METHODS: Subjects with HF (N = 29) were studied by measuring leptin, NPs, CO2 chemosensitivity (Δminute ventilation [V.e]/Δpartial pressure of end-tidal CO2 [Petco2]), and ventilatory efficiency (V.e/CO2 output [V.co2]) and were classified as CSA or no sleep-disordered breathing by polysomnography. CSA was defined as a central apnea-hypopnea index ≥ 15. The Student t test, Mann-Whitney U test, and logistic regression were used for analysis, and data were summarized as mean ± SD; P < .05 was considered significant.
RESULTS: Subjects with CSA had higher ANP and brain natriuretic peptide (BNP) concentrations (P < .05), ΔV.e/ΔPetco2 (2.39 ± 1.03 L/min/mm Hg vs 1.54 ± 0.35 L/min/mm Hg, P = .01), and V.e/V.co2 (43 ± 9 vs 34 ± 7, P < .01) and lower leptin concentrations (8 ± 10.7 ng/mL vs 17.1 ± 8.8 ng/mL, P < .01). Logistic regression analysis (adjusted for age, sex, and BMI) demonstrated leptin (OR = 0.07; 95% CI, 0.01-0.71; P = .04) and BNP (OR = 4.45; 95% CI, 1.1-17.9; P = .05) to be independently associated with CSA.
CONCLUSIONS: In patients with HF and CSA, leptin concentration is low and is inversely related to NP concentration. Counterregulatory interactions of leptin and NP may be important in ventilatory control in HF.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24030529      PMCID: PMC3883266          DOI: 10.1378/chest.12-2914

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  40 in total

Review 1.  Sleep apnea and heart failure: Part II: central sleep apnea.

Authors:  T Douglas Bradley; John S Floras
Journal:  Circulation       Date:  2003-04-08       Impact factor: 29.690

2.  Relation of natriuretic peptide concentrations to central sleep apnea in patients with heart failure.

Authors:  Andrew D Calvin; Virend K Somers; Christelle van der Walt; Christopher G Scott; Lyle J Olson
Journal:  Chest       Date:  2011-06-02       Impact factor: 9.410

3.  Leptin-induced cardioprotection involves JAK/STAT signaling that may be linked to the mitochondrial permeability transition pore.

Authors:  Christopher C T Smith; Richard A Dixon; Abigail M Wynne; Louise Theodorou; Sang-Ging Ong; Sapna Subrayan; Sean M Davidson; Derek J Hausenloy; Derek M Yellon
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-23       Impact factor: 4.733

Review 4.  The paradox of low BNP levels in obesity.

Authors:  Aldo Clerico; Alberto Giannoni; Simona Vittorini; Michele Emdin
Journal:  Heart Fail Rev       Date:  2012-01       Impact factor: 4.214

5.  Causes of breathing inefficiency during exercise in heart failure.

Authors:  Paul R Woods; Thomas P Olson; Robert P Frantz; Bruce D Johnson
Journal:  J Card Fail       Date:  2010-06-16       Impact factor: 5.712

6.  Raised sympathetic nerve activity in heart failure and central sleep apnea is due to heart failure severity.

Authors:  Darren Mansfield; David M Kaye; Hanspeter Brunner La Rocca; Peter Solin; Murray D Esler; Matthew T Naughton
Journal:  Circulation       Date:  2003-03-18       Impact factor: 29.690

7.  Enhanced ventilatory response to exercise in patients with chronic heart failure and central sleep apnea.

Authors:  Michael Arzt; Martina Harth; Andreas Luchner; Frank Muders; Stephan R Holmer; Friedrich C Blumberg; Günter A J Riegger; Michael Pfeifer
Journal:  Circulation       Date:  2003-04-14       Impact factor: 29.690

8.  Leptin reduces plasma ANP level via nitric oxide-dependent mechanism.

Authors:  Kuichang Yuan; Jiahua Yu; Amin Shah; Shan Gao; Sun Young Kim; Sung Zoo Kim; Byung-Hyun Park; Suhn Hee Kim
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2010-01-13       Impact factor: 3.619

9.  Effect of testosterone on the apneic threshold in women during NREM sleep.

Authors:  X S Zhou; J A Rowley; F Demirovic; M P Diamond; M S Badr
Journal:  J Appl Physiol (1985)       Date:  2002-09-13

Review 10.  The role of leptin in the respiratory system: an overview.

Authors:  Foteini Malli; Andriana I Papaioannou; Konstantinos I Gourgoulianis; Zoe Daniil
Journal:  Respir Res       Date:  2010-10-31
View more
  3 in total

1.  Exercise end-tidal CO2 predicts central sleep apnea in patients with heart failure.

Authors:  Ivan Cundrle; Virend K Somers; Bruce D Johnson; Christopher G Scott; Lyle J Olson
Journal:  Chest       Date:  2015-06       Impact factor: 9.410

2.  Low leptin concentration may identify heart failure patients with central sleep apnea.

Authors:  Ivan Cundrle; Virend K Somers; Prachi Singh; Bruce D Johnson; Christopher G Scott; Lyle J Olson
Journal:  J Sleep Res       Date:  2017-06-23       Impact factor: 3.981

3.  Obese Patients Experience More Severe CSA than Non-Obese Patients.

Authors:  Yao-Ching Huang; Shi-Hao Huang; Ren-Jei Chung; Bing-Long Wang; Chi-Hsiang Chung; Wu-Chien Chien; Chien-An Sun; Pi-Ching Yu; Chieh-Hua Lu
Journal:  Int J Environ Res Public Health       Date:  2022-01-24       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.