Literature DB >> 24029060

The role of ultrasonography in the evaluation of abdominal fat: analysis of technical and methodological issues.

Alberto Bazzocchi1, Giacomo Filonzi, Federico Ponti, Michele Amadori, Claudia Sassi, Eugenio Salizzoni, Ugo Albisinni, Giuseppe Battista.   

Abstract

RATIONALE AND
OBJECTIVES: Ultrasonography (US) is becoming popular for the assessment of adiposity, but no one has studied this tool in the light of its potential limitations. Our purpose was to investigate the impact of technical conditions on the evaluation of abdominal fat by US.
MATERIALS AND METHODS: Forty-five healthy males and 45 healthy females were consecutively enrolled in the study, randomly assigned to three groups equally distributed by sex, and examined accordingly to three technical points: fasting state (before and after meal [A]), breathing (expiration and inspiration [B]), and US equipment from different generations: 2003 and 1998 (C). Two blinded radiologists performed US in the these opposite conditions, acquiring five parameters representative of subcutaneous and visceral adiposity in two times. Student's t-test and Lin's correlation coefficient were used for statistical analysis to assess differences in the measures as well as in inter- and intra-observer agreements.
RESULTS: The maximum and the only statistically significant changes were observed for intra-abdominal fat thickness regarding fasting state and breathing (Δ% = 24.1 ± 21.3 and Δ% = 9.2 ± 20.4, respectively; P < .0001). Reproducibility and repeatability, especially for visceral fat, were proved more stable in the following conditions: fasting state, expiration, and newer machine (2003).
CONCLUSION: This article provides essential information and "range of confidence" for variations that can be expected from using different conditions in the measurement of abdominal adiposity by US to be carefully addressed as well as considered by US users and by researchers involving this technique in the field of body composition.
Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

Keywords:  Body composition; adiposity; methods; reproducibility of results; ultrasonography

Mesh:

Year:  2013        PMID: 24029060     DOI: 10.1016/j.acra.2013.07.009

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  3 in total

1.  Justification of anthropometric empirical indicator (AEI) by digital chest and pelvic X-rays: a comparative scenario with DXA on obesity grounds.

Authors:  K B Kishore Mohan; M Anburajan
Journal:  J Endocrinol Invest       Date:  2014-03-28       Impact factor: 4.256

2.  Genomic ancestry and education level independently influence abdominal fat distributions in a Brazilian admixed population.

Authors:  Giovanny Vinícius Araújo de França; Emanuella De Lucia Rolfe; Bernardo Lessa Horta; Denise Petrucci Gigante; John S Yudkin; Ken K Ong; Cesar Gomes Victora
Journal:  PLoS One       Date:  2017-06-05       Impact factor: 3.240

3.  Inter and intra-reliability of ultrasonography for the measurement of abdominal subcutaneous & visceral adipose tissue thickness at 12 weeks gestation.

Authors:  Alexandra Cremona; Kevin Hayes; Clodagh S O'Gorman; Ciara Ní Laighin; Khadijah I Ismail; Alan E Donnelly; Jill Hamilton; Amanda Cotter
Journal:  BMC Med Imaging       Date:  2019-12-17       Impact factor: 1.930

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.