Regional alveolar partial pressure of oxygen measurement with parallel accelerated hyperpolarized gas MRI.

Stephen Kadlecek1, Hooman Hamedani, Yinan Xu, Kiarash Emami, Yi Xin, Masaru Ishii, Rahim Rizi.   

Abstract

RATIONALE AND
OBJECTIVES: Alveolar oxygen tension (Pao2) is sensitive to the interplay between local ventilation, perfusion, and alveolar-capillary membrane permeability, and thus reflects physiologic heterogeneity of healthy and diseased lung function. Several hyperpolarized helium ((3)He) magnetic resonance imaging (MRI)-based Pao2 mapping techniques have been reported, and considerable effort has gone toward reducing Pao2 measurement error. We present a new Pao2 imaging scheme, using parallel accelerated MRI, which significantly reduces measurement error.
MATERIALS AND METHODS: The proposed Pao2 mapping scheme was computer-simulated and was tested on both phantoms and five human subjects. Where possible, correspondence between actual local oxygen concentration and derived values was assessed for both bias (deviation from the true mean) and imaging artifact (deviation from the true spatial distribution).
RESULTS: Phantom experiments demonstrated a significantly reduced coefficient of variation using the accelerated scheme. Simulation results support this observation and predict that correspondence between the true spatial distribution and the derived map is always superior using the accelerated scheme, although the improvement becomes less significant as the signal-to-noise ratio increases. Paired measurements in the human subjects, comparing accelerated and fully sampled schemes, show a reduced Pao2 distribution width for 41 of 46 slices.
CONCLUSION: In contrast to proton MRI, acceleration of hyperpolarized imaging has no signal-to-noise penalty; its use in Pao2 measurement is therefore always beneficial. Comparison of multiple schemes shows that the benefit arises from a longer time-base during which oxygen-induced depolarization modifies the signal strength. Demonstration of the accelerated technique in human studies shows the feasibility of the method and suggests that measurement error is reduced here as well, particularly at low signal-to-noise levels.
Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Hyperpolarized MRI; accelerated imaging; alveolar oxygen tension

Mesh:

Substances:

Year:  2013        PMID: 24029054      PMCID: PMC3856723          DOI: 10.1016/j.acra.2013.07.002

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  19 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Determination of regional VA/Q by hyperpolarized 3He MRI.

Authors:  Rahim R Rizi; James E Baumgardner; Masaru Ishii; Zebulon Z Spector; Johan M Edvinsson; Aman Jalali; Jiangsheng Yu; Maxim Itkin; David A Lipson; Warren Gefter
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

3.  Advantages of parallel imaging in conjunction with hyperpolarized helium--a new approach to MRI of the lung.

Authors:  Ray F Lee; Glyn Johnson; Robert I Grossman; Bernd Stoeckel; Robert Trampel; Georgeann McGuinness
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

4.  Optimization of scan parameters in pulmonary partial pressure oxygen measurement by hyperpolarized 3He MRI.

Authors:  Jiangsheng Yu; Masaru Ishii; Michelle Law; John M Woodburn; Kiarash Emami; Stephen Kadlecek; Vahid Vahdat; Richard A Guyer; Rahim R Rizi
Journal:  Magn Reson Med       Date:  2008-01       Impact factor: 4.668

5.  Nuclear relaxation of 3He in the presence of O2.

Authors: 
Journal:  Phys Rev A       Date:  1995-07       Impact factor: 3.140

6.  A flexible 32-channel receive array combined with a homogeneous transmit coil for human lung imaging with hyperpolarized 3He at 1.5 T.

Authors:  Martin H Deppe; Juan Parra-Robles; Helen Marshall; Titus Lanz; Jim M Wild
Journal:  Magn Reson Med       Date:  2011-05-13       Impact factor: 4.668

7.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

8.  Measurements of regional alveolar oxygen pressure using hyperpolarized 3He MRI.

Authors:  Martin C Fischer; Stephen Kadlecek; Jiangsheng Yu; Masaru Ishii; Kiarash Emami; Vahid Vahdat; David A Lipson; Rahim R Rizi
Journal:  Acad Radiol       Date:  2005-11       Impact factor: 3.173

9.  Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by (3)He MRI.

Authors:  A J Deninger; B Eberle; M Ebert; T Grossmann; W Heil; H Kauczor; L Lauer; K Markstaller; E Otten; J Schmiedeskamp; W Schreiber; R Surkau; M Thelen; N Weiler
Journal:  J Magn Reson       Date:  1999-12       Impact factor: 2.229

10.  Measurement of pulmonary partial pressure of oxygen and oxygen depletion rate with hyperpolarized helium-3 MRI: a preliminary reproducibility study on pig model.

Authors:  Jiangsheng Yu; Sheeva Rajaei; Masaru Ishii; Michelle Law; Kiarash Emami; John M Woodburn; Stephen Kadlecek; Vahid Vahdat; Rahim R Rizi
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

View more
  1 in total

Review 1.  Functional imaging of the lungs with gas agents.

Authors:  Stanley J Kruger; Scott K Nagle; Marcus J Couch; Yoshiharu Ohno; Mitchell Albert; Sean B Fain
Journal:  J Magn Reson Imaging       Date:  2015-07-27       Impact factor: 4.813

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.