Literature DB >> 24028385

Reproducibility in echocardiographic two- and three-dimensional mitral valve assessment.

Maximilian Dominik Hien1, Manuel Großgasteiger, Alexander Weymann, Helmut Rauch, Christian Rosendal.   

Abstract

BACKGROUND: Three-dimensional transesophageal echocardiography (3DTEE) has been demonstrated to provide more accurate information than two-dimensional transesophageal echocardiography (2DTEE) in the localization of mitral valve prolapse (MVP). However, most studies have been single-rater studies. Few results were tested for inter-observer variability with a single second rater. This multicenter study aimed to determine reliability of 2D and 3DTEE mitral valve evaluations by calculating inter-observer agreement between various echocardiographers.
METHODS: Fifteen observers from 4 institutions in Germany and Switzerland interpreted 2D and 3DTEE images from 6 patients selected to represent a large spectrum of MVP diversity. Surgical findings served as reference. Individual assessments of MVP and ruptured chordae tendineae (ChR) pathology were compared by calculating Randolph's free-marginal multirater kappa coefficient.
RESULTS: Accuracy of MVP evaluation with 3DTEE was 83.9%, CI [81.0%; 86.8%] and 78.7% CI [76.6% 80.8%] with 2DTEE. Flail leaflets with chordal ruptures were described correctly in 91.1%, CI [85.8, 96.4] with 3D compared to 71.1%, CI [65.0, 77.2] with 2DTEE. The multirater kappa coefficient of inter-observer agreement among all 15 observers was κ = 0.65/0.58 for 3D/2D evaluation of MVP and κ = 0.70/0.54 for detection of ChR.
CONCLUSION: Three-dimensional assessment of MVP was superior to 2DTEE, although the accuracy of both 3DTEE and 2DTEE was found to be lower than previously published. 3D MVP assessment is less operator dependent than 2DTEE evaluation. Although validity has been demonstrated before, we provide evidence that 3DTEE is reproducible among 15 observers and is a reliable method for MVP evaluation.
© 2013, Wiley Periodicals, Inc.

Entities:  

Keywords:  inter-observer agreement; inter-observer variability; mitral valve prolapse evaluation; multicenter study; reliability; ruptured chordae tendineae

Mesh:

Year:  2013        PMID: 24028385     DOI: 10.1111/echo.12365

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  3 in total

1.  Computed tomography for planning and postoperative imaging of transvenous mitral annuloplasty: first experience in an animal model.

Authors:  Simon H Sündermann; Sonja Gordic; Robert Manka; Nikola Cesarovic; Volkmar Falk; Francesco Maisano; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-15       Impact factor: 2.357

2.  Impact of real-time three-dimensional transesophageal echocardiography on procedural success for mitral valve repair.

Authors:  Mika Mori; Tsuyoshi Yoshimuta; Miho Ohira; Mariko Yagi; Kenji Sakata; Tetsuo Konno; Masa-aki Kawashiri; Shigeyuki Tomita; Go Watanabe; Kenji Iino; Hirofumi Takemura; Masakazu Yamagishi; Kenshi Hayashi
Journal:  J Echocardiogr       Date:  2015-07-30

Review 3.  The mechanisms, diagnosis and management of mitral regurgitation in mitral valve prolapse and hypertrophic cardiomyopathy.

Authors:  Mihaela Octavia Popa; Ana Maria Irimia; Mihai Nicolae Papagheorghe; Elena Miruna Vasile; Simona Andreea Tircol; Raluca Andreea Negulescu; Catalina Toader; Robert Adam; Lucian Dorobantu; Cristina Caldararu; Maria Alexandrescu; Sebastian Onciul
Journal:  Discoveries (Craiova)       Date:  2016-06-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.