BACKGROUND: Although it is recognized that pulmonary hysteresis can influence the effects of positive end-expiratory pressure (PEEP), the extent to which expansion of previously opened (vs. newly opening) peripheral airspaces contribute to increased lung volume is unknown. METHODS: Following a recruitment maneuver, rats were ventilated with constant tidal volumes and imaged during ascending and descending ramps of PEEP. RESULTS: The authors estimated peripheral airspace dimensions by measuring the apparent diffusion coefficient of He in 10 rats. In a separate group (n = 5) undergoing a similar protocol, the authors used computerized tomography to quantify lung volume. Hysteresis was confirmed by larger end-inspiratory lung volume (mean ± SD; all PEEP levels included): 8.4 ± 2.8 versus 6.8 ± 2.0 ml (P < 0.001) and dynamic compliance: 0.52 ± 0.12 versus 0.42 ± 0.09 ml/cm H2O (P < 0.001) during descending versus ascending PEEP ramps. Apparent diffusion coefficient increased with PEEP, but it was smaller during the descending versus ascending ramps for corresponding levels of PEEP: 0.168 ± 0.019 versus 0.183 ± 0.019 cm/s (P < 0.001). Apparent diffusion coefficient was smaller in the posterior versus anterior lung regions, but the effect of PEEP and hysteresis on apparent diffusion coefficient was greater in the posterior regions. CONCLUSIONS: The authors' study results suggest that in healthy lungs, larger lung volumes due to hysteresis are associated with smaller individual airspaces. This may be explained by opening of previously nonaerated peripheral airspaces rather than expansion of those already aerated. Setting PEEP on a descending ramp may minimize distension of individual airspaces.
BACKGROUND: Although it is recognized that pulmonary hysteresis can influence the effects of positive end-expiratory pressure (PEEP), the extent to which expansion of previously opened (vs. newly opening) peripheral airspaces contribute to increased lung volume is unknown. METHODS: Following a recruitment maneuver, rats were ventilated with constant tidal volumes and imaged during ascending and descending ramps of PEEP. RESULTS: The authors estimated peripheral airspace dimensions by measuring the apparent diffusion coefficient of He in 10 rats. In a separate group (n = 5) undergoing a similar protocol, the authors used computerized tomography to quantify lung volume. Hysteresis was confirmed by larger end-inspiratory lung volume (mean ± SD; all PEEP levels included): 8.4 ± 2.8 versus 6.8 ± 2.0 ml (P < 0.001) and dynamic compliance: 0.52 ± 0.12 versus 0.42 ± 0.09 ml/cm H2O (P < 0.001) during descending versus ascending PEEP ramps. Apparent diffusion coefficient increased with PEEP, but it was smaller during the descending versus ascending ramps for corresponding levels of PEEP: 0.168 ± 0.019 versus 0.183 ± 0.019 cm/s (P < 0.001). Apparent diffusion coefficient was smaller in the posterior versus anterior lung regions, but the effect of PEEP and hysteresis on apparent diffusion coefficient was greater in the posterior regions. CONCLUSIONS: The authors' study results suggest that in healthy lungs, larger lung volumes due to hysteresis are associated with smaller individual airspaces. This may be explained by opening of previously nonaerated peripheral airspaces rather than expansion of those already aerated. Setting PEEP on a descending ramp may minimize distension of individual airspaces.
Authors: D E Carney; C E Bredenberg; H J Schiller; A L Picone; U G McCann; L A Gatto; G Bailey; M Fillinger; G F Nieman Journal: Am J Respir Crit Care Med Date: 1999-11 Impact factor: 21.405
Authors: Roy G Brower; Michael A Matthay; Alan Morris; David Schoenfeld; B Taylor Thompson; Arthur Wheeler Journal: N Engl J Med Date: 2000-05-04 Impact factor: 91.245
Authors: Michelle Duggan; Conán L McCaul; Patrick J McNamara; Doreen Engelberts; Cameron Ackerley; Brian P Kavanagh Journal: Am J Respir Crit Care Med Date: 2003-03-27 Impact factor: 21.405
Authors: Kelly K Brewer; Hiroaki Sakai; Adriano M Alencar; Arnab Majumdar; Stephen P Arold; Kenneth R Lutchen; Edward P Ingenito; Béla Suki Journal: J Appl Physiol (1985) Date: 2003-07-18
Authors: Maurizio Cereda; Kiarash Emami; Yi Xin; Stephen Kadlecek; Nicholas N Kuzma; Puttisarn Mongkolwisetwara; Harrilla Profka; Stephen Pickup; Masaru Ishii; Brian P Kavanagh; Clifford S Deutschman; Rahim R Rizi Journal: Crit Care Med Date: 2013-02 Impact factor: 7.598
Authors: Maurizio Cereda; Yi Xin; Hooman Hamedani; Justin Clapp; Stephen Kadlecek; Natalie Meeder; Johnathan Zeng; Harrilla Profka; Brian P Kavanagh; Rahim R Rizi Journal: J Appl Physiol (1985) Date: 2015-12-10
Authors: Yi Xin; Gang Song; Maurizio Cereda; Stephen Kadlecek; Hooman Hamedani; Yunqing Jiang; Jennia Rajaei; Justin Clapp; Harrilla Profka; Natalie Meeder; Jue Wu; Nicholas J Tustison; James C Gee; Rahim R Rizi Journal: J Appl Physiol (1985) Date: 2014-11-13
Authors: Margit V Szabari; Kazue Takahashi; Yan Feng; Joseph J Locascio; Wei Chao; Edward A Carter; Marcos F Vidal Melo; Guido Musch Journal: Am J Respir Cell Mol Biol Date: 2019-02 Impact factor: 6.914
Authors: Yi Xin; Maurizio Cereda; Stephen Kadlecek; Kiarash Emami; Hooman Hamedani; Ian Duncan; Jennia Rajaei; Liam Hughes; Natalie Meeder; Joseph Naji; Harrilla Profka; Brian J Bolognese; Joseph P Foley; Patricia L Podolin; Rahim R Rizi Journal: Am J Physiol Lung Cell Mol Physiol Date: 2017-05-04 Impact factor: 5.464
Authors: Maurizio Cereda; Yi Xin; Natalie Meeder; Johnathan Zeng; YunQing Jiang; Hooman Hamedani; Harrilla Profka; Stephen Kadlecek; Justin Clapp; Charuhas G Deshpande; Jue Wu; James C Gee; Brian P Kavanagh; Rahim R Rizi Journal: Anesthesiology Date: 2016-01 Impact factor: 7.892
Authors: Maurizio Cereda; Yi Xin; Alberto Goffi; Jacob Herrmann; David W Kaczka; Brian P Kavanagh; Gaetano Perchiazzi; Takeshi Yoshida; Rahim R Rizi Journal: Anesthesiology Date: 2019-09 Impact factor: 7.892