Literature DB >> 24024306

Intracranial pressure and optic nerve sheath diameter as cephalic venous pressure increases in swine.

Derek M Nusbaum1, Jonathan B Clark, Kenneth M Brady, Kathleen K Kibler, Jeffrey P Sutton, R Blaine Easley.   

Abstract

BACKGROUND: Nontraumatic, nonhydrocephalic increases in intracranial pressure (ICP) are often difficult to diagnose and may underlie spaceflight-related visual changes. This study looked at the utility of a porcine animal model of increasing cephalic venous pressure to mimic acute changes in ICP and optic nerve sheath diameter (ONSD) from cephalic venous fluid shifts observed during spaceflight.
METHODS: Anesthetized juvenile piglets were assigned to groups of either naïve (N = 10) or elevated superior vena cava pressure (SVCP; N = 20). To elevate SVCP, a 6F custom latex balloon catheter was inserted and inflated to achieve SVCP of 20 and 40 mmHg for 1 h at each pressure. In both groups, serial measurements of ICP, internal jugular pressure (IJP), and external jugular pressure (EJP) were made hourly for 3 h, and ONSD of the right eye was measured hourly by ultrasound (US).
RESULTS: There was a significant linear correlation between IJP and ICP (slope: 0.9614 +/- 0.0038, r = 0.9683). With increasing SVCP, resulting ONSD was also well correlated with the ICP (slope: 0.0958 +/- 0.0061, r = 0.7841). The receiver operating characteristic curve for ONSD in diagnosing elevated ICP had an area under the curve of 0.9632 with a sensitivity and specificity of 92% and 91%, respectively, for a cutoff of 5.45 mm.
CONCLUSIONS: Increases in SVCP result in ICP changes that are well correlated with alteration in ONSD. These changes are consistent with observed ONSD changes monitored during spaceflight.

Entities:  

Mesh:

Year:  2013        PMID: 24024306     DOI: 10.3357/asem.3486.2013

Source DB:  PubMed          Journal:  Aviat Space Environ Med        ISSN: 0095-6562


  4 in total

1.  Internal jugular pressure increases during parabolic flight.

Authors:  David S Martin; Stuart M C Lee; Timothy P Matz; Christian M Westby; Jessica M Scott; Michael B Stenger; Steven H Platts
Journal:  Physiol Rep       Date:  2016-12

2.  Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs.

Authors:  R Mija; I Zubak; A Schuetz; M Glas; C Fung; S M Jakob; J Beck; W J Z'Graggen; Andreas Bloch
Journal:  PLoS One       Date:  2020-02-04       Impact factor: 3.240

Review 3.  Optic Nerve Ultrasound Evaluation in Animals and Normal Subjects.

Authors:  Livio Vitiello; Maddalena De Bernardo; Luigi Capasso; Palmiro Cornetta; Nicola Rosa
Journal:  Front Med (Lausanne)       Date:  2022-01-05

Review 4.  Optic nerve sheath diameter and spaceflight: defining shortcomings and future directions.

Authors:  Dylan A Fall; Andrew G Lee; Eric M Bershad; Larry A Kramer; Thomas H Mader; Jonathan B Clark; Mohammad I Hirzallah
Journal:  NPJ Microgravity       Date:  2022-10-06       Impact factor: 4.970

  4 in total