Literature DB >> 24021832

Sequential cloud-point extraction for toxicological screening analysis of medicaments in human plasma by high pressure liquid chromatography with diode array detector.

Katarzyna Madej1, Karolina Persona, Monika Wandas, Ewa Gomółka.   

Abstract

A complex extraction system with the use of cloud-point extraction technique (CPE) was developed for sequential isolation of basic and acidic/neutral medicaments from human plasma/serum, screened by HPLC/DAD method. Eight model drugs (paracetamol, promazine, chlorpromazine, amitriptyline, salicyclic acid, opipramol, alprazolam and carbamazepine) were chosen for the study of optimal CPE conditions. The CPE technique consists in partition of an aqueous sample with addition of a surfactant into two phases: micelle-rich phase with the isolated compounds and water phase containing a surfactant below the critical micellar concentration, mainly under influence of temperature change. The proposed extraction system consists of two chief steps: isolation of basic compounds (from pH 12) and then isolation of acidic/neutral compounds (from pH 6) using surfactant Triton X-114 as the extraction medium. Extraction recovery varied from 25.2 to 107.9% with intra-day and inter-day precision (RSD %) ranged 0.88-1087 and 5.32-17.96, respectively. The limits of detection for the studied medicaments at λ 254nm corresponded to therapeutic or low toxic plasma concentration levels. Usefulness of the proposed CPE-HPLC/DAD method for toxicological drug screening was tested via its application to analysis of two serum samples taken from patients suspected of drug overdosing. Published by Elsevier B.V.

Entities:  

Keywords:  Cloud-point extraction; HPLC/DAD; Medicaments; Plasma/serum samples; Toxicological drug screening

Mesh:

Substances:

Year:  2013        PMID: 24021832     DOI: 10.1016/j.chroma.2013.08.093

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

Review 1.  Cloud point extraction coupled with back extraction: a green methodology in analytical chemistry.

Authors:  Shivpoojan Kori
Journal:  Forensic Sci Res       Date:  2019-09-18

2.  Enantioseparation of phenothiazines through capillary electrophoresis with solid phase extraction and polymer based stacking.

Authors:  Wei-Bin Tseng; Ming-Mu Hsieh; Tai-Chia Chiu; Po-Lin Yu; Szu-Hua Chen
Journal:  J Food Drug Anal       Date:  2018-01-12       Impact factor: 6.157

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.