The simple, selective, precise and accurate reverse-phase high-performance liquid chromatography method was developed and validated for analysis of tadalafil in bulk and tablet dosage form. The column was Inertsil C18 (150×4.6 mm; 5 μm) in isocratic mode. The mobile phase used was phosphate buffer (10 mM, pH 3.2) and acetonitrile (50:50% v/v) at the flow rate of 1.0 ml/min with ultraviolet detection at 295 nm at ambient temperature. The retention time for tadalafil was found to be 4.01 min. Linearity was observed in the concentration range from 60 to 140 μg/ml for tadalafil with a correlation coefficient of (r (2)) 0.9998. The method was validated according to International Conference on Harmonisation guidelines in terms of linearity, accuracy, precision and specificity. Hence, the proposed method can be utilized for routine quality control of tadalafil in bulk and tablet dosage form.Entities:
Keywords: International conference on harmonisation guidelines; reverse phase high performance liquid chromatography; tadalafil; ultraviolet detection; validation
Year: 2013 PMID: 24019575 PMCID: PMC3757865
Source DB: PubMed Journal: Indian J Pharm Sci ISSN: 0250-474X Impact factor: 0.975
Fig. 1Structure of tadalafil.
Fig. 2Typical chromatogram of tadalafil at 295 nm.
VALIDATION AND SYSTEM SUITABILITY PARAMETERS
RECOVERY STUDY OF TADALAFIL (TABLET) N=3
INTERMEDIATE PRECISION AND SYSTEM SUITABILITY STUDIES OF TADALAFIL