Literature DB >> 2401736

Reticulocyte counting using flow cytometry.

P R Nobes1, A B Carter.   

Abstract

A flow cytometric method for the quantitation of reticulocytes was refined for routine laboratory use. Blood (2 microliters) is added to 2 ml of 0.4 microM thiazole orange in phosphate buffered saline, incubated at room temperature for 90 minutes, and analysed on a Coulter EPICS Profile flow cytometer, with gating for red cells on the basis of forward and right angled light scatter. Blood (2 microliters) is also incubated with phosphate buffered saline alone as an unstained control. The adult reference range (mean +/- 2 SD), established from 30 laboratory personnel, is 19.4-59.2 x 10(9)/l (0.2-1.6%). Comparison of this technique was made on 39 selected patient samples with visual counting of cells stained with brilliant cresyl blue. The correlation between the two methods was 0.99 with slope 0.96 and intercept 0.02. The precision of the automated technique in three subjects with reticulocyte counts of 0.12%, 1.84%, and 14.3% was 33.3%, 7.3%, and 1.4%, respectively (coefficient of variations). In three patients studied serially after intensive chemotherapy, in whom the reticulocyte count quantitated by routine visual methods approached zero (0-0.1%) for eight to 18 days, the automated counts varied between 0 and 0.5%. Flow cytometric reticulocyte counting is thus a simple and highly reliable methodology for the quantitation of normal and raised reticulocyte counts but cannot be reliably used to quantitate a subnormal level.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2401736      PMCID: PMC502653          DOI: 10.1136/jcp.43.8.675

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  3 in total

1.  An automated reticulocyte counting method: preliminary observations.

Authors:  N Tatsumi; I Tsuda; K Kojima; M Niri; K Setoguchi
Journal:  Med Lab Sci       Date:  1989-04

2.  A time-saving device for the counting of reticulocytes.

Authors:  G BRECHER; M SCHNEIDERMAN
Journal:  Am J Clin Pathol       Date:  1950-11       Impact factor: 2.493

3.  Thiazole orange: a new dye for reticulocyte analysis.

Authors:  L G Lee; C H Chen; L A Chiu
Journal:  Cytometry       Date:  1986-11
  3 in total
  17 in total

Review 1.  Reticulocytes and reticulocyte enumeration.

Authors:  R S Riley; J M Ben-Ezra; R Goel; A Tidwell
Journal:  J Clin Lab Anal       Date:  2001       Impact factor: 2.352

2.  Erythrocyte maturation in neonatal dwarf and landrace kids.

Authors:  G K Mbassa; J S Poulsen
Journal:  Vet Res Commun       Date:  1991       Impact factor: 2.459

3.  NIX is required for programmed mitochondrial clearance during reticulocyte maturation.

Authors:  Rachel L Schweers; Ji Zhang; Mindy S Randall; Melanie R Loyd; Weimin Li; Frank C Dorsey; Mondira Kundu; Joseph T Opferman; John L Cleveland; Jeffery L Miller; Paul A Ney
Journal:  Proc Natl Acad Sci U S A       Date:  2007-11-29       Impact factor: 11.205

4.  Prothrombin activation in blood coagulation: the erythrocyte contribution to thrombin generation.

Authors:  Matthew F Whelihan; Vicentios Zachary; Thomas Orfeo; Kenneth G Mann
Journal:  Blood       Date:  2012-09-11       Impact factor: 22.113

Review 5.  Exercise, training and red blood cell turnover.

Authors:  J A Smith
Journal:  Sports Med       Date:  1995-01       Impact factor: 11.136

6.  Amelioration of inflammation and tissue damage in sickle cell model mice by Nrf2 activation.

Authors:  Nadine Keleku-Lukwete; Mikiko Suzuki; Akihito Otsuki; Kouhei Tsuchida; Saori Katayama; Makiko Hayashi; Eriko Naganuma; Takashi Moriguchi; Osamu Tanabe; James Douglas Engel; Masue Imaizumi; Masayuki Yamamoto
Journal:  Proc Natl Acad Sci U S A       Date:  2015-09-14       Impact factor: 11.205

7.  The appearance of reticulocytes with medium or high RNA content is a sensitive indicator of beginning granulocyte recovery after aplasiogenic cytostatic drug therapy in patients with AML.

Authors:  R Kuse
Journal:  Ann Hematol       Date:  1993-04       Impact factor: 3.673

8.  An in vivo drug screening model using glucose-6-phosphate dehydrogenase deficient mice to predict the hemolytic toxicity of 8-aminoquinolines.

Authors:  Peng Zhang; Xiugong Gao; Hiroshi Ishida; Jack Amnuaysirikul; Peter J Weina; Max Grogl; Michael T O'Neil; Qigui Li; Diana Caridha; Colin Ohrt; Mark Hickman; Alan J Magill; Prabhati Ray
Journal:  Am J Trop Med Hyg       Date:  2013-03-25       Impact factor: 2.345

9.  Isocitrate ameliorates anemia by suppressing the erythroid iron restriction response.

Authors:  Chanté L Richardson; Lorrie L Delehanty; Grant C Bullock; Claudia M Rival; Kenneth S Tung; Donald L Kimpel; Sara Gardenghi; Stefano Rivella; Adam N Goldfarb
Journal:  J Clin Invest       Date:  2013-07-25       Impact factor: 14.808

Review 10.  Global assays of hemostasis.

Authors:  Kathleen E Brummel-Ziedins; Alisa S Wolberg
Journal:  Curr Opin Hematol       Date:  2014-09       Impact factor: 3.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.