Quantification of incisal tooth wear in upper anterior teeth: conventional vs new method using toolmakers microscope and a three-dimensional measuring technique.

Mahmoud K Al-Omiri1, Mohd G Sghaireen, Bader K Alzarea, Edward Lynch.   

Abstract

OBJECTIVES: This study aimed to quantify tooth wear in upper anterior teeth using a new CAD-CAM Laser scanning machine, tool maker microscope and conventional tooth wear index.
METHODS: Fifty participants (25 males and 25 females, mean age = 25 ± 4 years) were assessed for incisal tooth wear of upper anterior teeth using Smith and Knight clinical tooth wear index (TWI) on two occasions, the study baseline and 1 year later. Stone dies for each tooth were prepared and scanned using the CAD-CAM Laser Cercon System. Scanned images were printed and examined under a toolmaker microscope to quantify tooth wear and then the dies were directly assessed under the microscope to measure tooth wear. The Wilcoxon Signed Ranks Test was used to analyze the data.
RESULTS: TWI scores for incisal edges were 0-3 and were similar at both occasions. Score 4 was not detected. Wear values measured by directly assessing the dies under the toolmaker microscope (range = 113 - 150 μm, mean = 130 ± 20 μm) were significantly more than those measured from Cercon Digital Machine images (range=52-80 μm, mean = 68 ± 23 μm) and both showed significant differences between the two occasions.
CONCLUSIONS: Wear progression in upper anterior teeth was effectively detected by directly measuring the dies or the images of dies under toolmaker microscope. Measuring the dies of worn dentition directly under tool maker microscope enabled detection of wear progression more accurately than measuring die images obtained with Cercon Digital Machine. Conventional method was the least sensitive for tooth wear quantification and was unable to identify wear progression in most cases.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D measuring; Cercon brain machine; Tool makers microscope; Tooth wear; Tooth wear index

Mesh:

Year:  2013        PMID: 24012517     DOI: 10.1016/j.jdent.2013.08.022

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  2 in total

1.  The Prevalence of Tooth Wear in an Adult Population from the Eastern Province of Saudi Arabia.

Authors:  Khalifa S Al-Khalifa
Journal:  Clin Cosmet Investig Dent       Date:  2020-11-17

2.  3D Method for Occlusal Tooth Wear Assessment in Presence of Substantial Changes on Other Tooth Surfaces.

Authors:  Nikolaos Gkantidis; Konstantinos Dritsas; Christos Katsaros; Demetrios Halazonetis; Yijin Ren
Journal:  J Clin Med       Date:  2020-12-04       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.