Literature DB >> 24012202

Lens wearers non-compliance - is there an association with lens case contamination?

Tomislav Kuzman1, Marija Barišić Kutija2, Jelena Juri3, Sonja Jandroković2, Ivan Skegro2, Sanja Masnec Olujić2, Rajko Kordić3, Branimir Cerovski3.   

Abstract

PURPOSE: This study aims to investigate the association of compliance amongst lens wearers and lens case contamination as assessed by the microbial profile of lens cases.
METHODS: Fifty-two asymptomatic lens wearers filled out questionnaires seeking demographic data and several aspects of compliance to lens wear. Subsequently, contamination profiles of the inside bottom and rim of their lens cases was obtained for bacteria, fungi and Acanthamoeba. The association of the self-reported responses in the questionnaire with contamination profile of the lens case was then analyzed.
RESULTS: Based on compliance criteria, 21% of the participants were described as fully compliant lens wearers. Contamination of lens case was prevalent in 42% of the cases. Frequent non-compliant behaviours reported by study participants included, showering and sleeping with contact lenses, and irregular lens case replacement. In comparison to soft contact lens wearers prevalence of non-compliance and contamination amongst rigid gas permeable (RGP) lens wearers was significantly greater. There was a statistically significant correlation between bacterial contamination and current case age.
CONCLUSION: These results suggest that majority of lens wearers do not fully comply with recommendations for lens wear and case care. Crucially, none of the fully compliant patients had contaminated lens cases. However it would appear that several non-compliant behaviours significantly increase the risks of case contamination. These results suggest that greater efforts should be invested with lens wearers to ensure enhanced compliance as this is likely to reduce the possibility of case contamination.
Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Case contamination; Case replacement; Compliance; Contact lens; Non-compliance

Mesh:

Year:  2013        PMID: 24012202     DOI: 10.1016/j.clae.2013.08.004

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  4 in total

1.  Identifying the content, functionalities, and features of a mobile application for contact lens wearers.

Authors:  Fatemeh Falahati-Marvast; Andrew D Pucker; Fateme Alipour; Jamileh Farokhzadian; Leila Ahmadian
Journal:  BMC Med Inform Decis Mak       Date:  2022-06-21       Impact factor: 3.298

2.  PCR analysis for assessment of bacterial bioburden in orthokeratology lens cases.

Authors:  Jung Lo; Po-Chiung Fang; Chun-Chih Chien; Chang-Chun Hsiao; Shin-Ling Tseng; Yu-Hsuan Lai; Ming-Tse Kuo
Journal:  Mol Vis       Date:  2016-01-14       Impact factor: 2.367

3.  Bacterial Bioburden Decrease in Orthokeratology Lens Storage Cases After Forewarning: Assessment by the DNA Dot Hybridization Assay.

Authors:  Po-Chiung Fang; Jung Lo; Tsung C Chang; Chun-Chih Chien; Chang-Chun Hsiao; Shin-Ling Tseng; Yu-Hsuan Lai; Ming-Tse Kuo
Journal:  Eye Contact Lens       Date:  2017-05       Impact factor: 2.018

4.  In Vitro Antimicrobial Efficacy of Silver Lens Cases Used With a Multipurpose Disinfecting Solution.

Authors:  Ananya Datta; Mark Willcox; Fiona Stapleton
Journal:  Transl Vis Sci Technol       Date:  2019-06-27       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.