Literature DB >> 24011956

Comparisons of surface vs. volumetric model-based registration methods using single-plane vs. bi-plane fluoroscopy in measuring spinal kinematics.

Cheng-Chung Lin1, Tung-Wu Lu2, Ting-Ming Wang3, Chao-Yu Hsu4, Ting-Fang Shih5.   

Abstract

Several 2D-to-3D image registration methods are available for measuring 3D vertebral motion but their performance has not been evaluated under the same experimental protocol. In this study, four major types of fluoroscopy-to-CT registration methods, with different use of surface vs. volumetric models, and single-plane vs. bi-plane fluoroscopy, were evaluated: STS (surface, single-plane), VTS (volumetric, single-plane), STB (surface, bi-plane) and VTB (volumetric, bi-plane). Two similarity measures were used: 'Contour Difference' for STS and STB and 'Weighted Edge-Matching Score' for VTS and VTB. Two cadaveric porcine cervical spines positioned in a box filled with paraffin and embedded with four radiopaque markers were CT scanned to obtain vertebral models and marker coordinates, and imaged at ten static positions using bi-plane fluoroscopy for subsequent registrations using different methods. The registered vertebral poses were compared to the gold standard poses defined by the marker positions determined using CT and Roentgen stereophotogrammetry analysis. The VTB was found to have the highest precision (translation: 0.4mm; rotation: 0.3°), comparable with the VTS in rotations (0.3°), and the STB in translations (0.6mm). The STS had the lowest precision (translation: 4.1mm; rotation: 2.1°).
Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CT; Fluoroscopy; Kinematics; Registration; Spine

Mesh:

Year:  2013        PMID: 24011956     DOI: 10.1016/j.medengphy.2013.08.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  2 in total

1.  Quantification of three-dimensional soft tissue artifacts in the canine hindlimb during passive stifle motion.

Authors:  Cheng-Chung Lin; Chia-Lin Chang; Ming Lu; Tung-Wu Lu; Ching-Ho Wu
Journal:  BMC Vet Res       Date:  2018-12-07       Impact factor: 2.741

2.  Effects of Internal Fixation for Mid-Shaft Clavicle Fractures on Shoulder Kinematics During Humeral Elevations.

Authors:  Li-Wei Hung; Hsuan-Yu Lu; Chung-Hsun Chang; Tsan-Yang Chen; Ting-Ming Wang; Tung-Wu Lu
Journal:  Front Bioeng Biotechnol       Date:  2021-07-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.