Literature DB >> 2400896

Comparison of spin echo T1-weighted and FLASH 90 degrees gadolinium-enhanced magnetic resonance imaging in the detection of cerebral metastases.

G Cherryman1, R Golfieri.   

Abstract

A direct comparison of post-gadolinium FLASH 90 degrees magnetic resonance (MR) images against conventional post-gadolinium T1-weighted spin echo MR images obtained in patients with suspected cerebral metastatic disease shows the FLASH sequence to be inferior. False negative FLASH 90 degrees gadolinium-enhanced MR scans are thought to be a result of either magnetic susceptibility artefact or inferior contrast resolution. False positive FLASH 90 degrees gadolinium-enhanced MR images are a result of either difficulty in interpreting the high signal seen in small vessels or, again, magnetic susceptibility effects. In addition, our study shows small abnormalities suggestive of cerebral metastases on the FLASH 90 degrees gadolinium-enhanced sequences which were not seen on the spin echo T1-weighted gadolinium-enhanced sequences. We believe that spin echo T1-weighted gadolinium-enhanced MR sequences demonstrated 131 out of 139 (94.2%) and FLASH 90 degrees gadolinium-enhanced MR sequences detected 122 out of 139 (87.8%) possible metastases. From this, we conclude that spin echo T1-weighted gadolinium-enhanced MR sequences is a better test than FLASH 90 degrees gadolinium-enhanced MR in the diagnosis of brain metastases and that either sequence alone is limited as a screening test.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2400896     DOI: 10.1259/0007-1285-63-753-712

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Clinical usefulness of contrast-enhanced MP-RAGE of the brain.

Authors:  L van den Hauwe; P M Parizel; J W Van Goethem; A M De Schepper
Journal:  Neuroradiology       Date:  1996-05       Impact factor: 2.804

2.  Quantitative contrast ratio comparison between T1 (TSE at 1.5T, FLAIR at 3T), magnetization prepared rapid gradient echo and subtraction imaging at 1.5T and 3T.

Authors:  Richard Keith Downs; Mariah Haider Bashir; Chin Kau Ng; Jens Olaf Heidenreich
Journal:  Quant Imaging Med Surg       Date:  2013-06

Review 3.  Brain metastases: An update on the multi-disciplinary approach of clinical management.

Authors:  D K Mitchell; H J Kwon; P A Kubica; W X Huff; R O'Regan; M Dey
Journal:  Neurochirurgie       Date:  2021-04-14       Impact factor: 1.553

4.  Demographic and clinical profile of patients with brain metastases: A retrospective study.

Authors:  Animesh Saha; Sajal Kumar Ghosh; Chhaya Roy; Krishnangshu Bhanja Choudhury; Bikramjit Chakrabarty; Ratan Sarkar
Journal:  Asian J Neurosurg       Date:  2013-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.