Literature DB >> 24007613

Measurement of structural anisotropy in femoral trabecular bone using clinical-resolution CT images.

Mariana E Kersh1, Philippe K Zysset, Dieter H Pahr, Uwe Wolfram, David Larsson, Marcus G Pandy.   

Abstract

Discrepancies in finite-element model predictions of bone strength may be attributed to the simplified modeling of bone as an isotropic structure due to the resolution limitations of clinical-level Computed Tomography (CT) data. The aim of this study is to calculate the preferential orientations of bone (the principal directions) and the extent to which bone is deposited more in one direction compared to another (degree of anisotropy). Using 100 femoral trabecular samples, the principal directions and degree of anisotropy were calculated with a Gradient Structure Tensor (GST) and a Sobel Structure Tensor (SST) using clinical-level CT. The results were compared against those calculated with the gold standard Mean-Intercept-Length (MIL) fabric tensor using micro-CT. There was no significant difference between the GST and SST in the calculation of the main principal direction (median error=28°), and the error was inversely correlated to the degree of transverse isotropy (r=-0.34, p<0.01). The degree of anisotropy measured using the structure tensors was weakly correlated with the MIL-based measurements (r=0.2, p<0.001). Combining the principal directions with the degree of anisotropy resulted in a significant increase in the correlation of the tensor distributions (r=0.79, p<0.001). Both structure tensors were robust against simulated noise, kernel sizes, and bone volume fraction. We recommend the use of the GST because of its computational efficiency and ease of implementation. This methodology has the promise to predict the structural anisotropy of bone in areas with a high degree of anisotropy, and may improve the in vivo characterization of bone.
© 2013 Elsevier Ltd. All rights reserved.

Keywords:  Clinical quantitative computed tomography; Finite-element model; Gradient structure tensor; Sobel structure tensor; Trabecular bone strength

Mesh:

Year:  2013        PMID: 24007613     DOI: 10.1016/j.jbiomech.2013.07.047

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Computer-based automatic classification of trabecular bone pattern can assist radiographic bone quality assessment at dental implant site.

Authors:  Laura Ferreira Pinheiro Nicolielo; Jeroen Van Dessel; G Harry van Lenthe; Ivo Lambrichts; Reinhilde Jacobs
Journal:  Br J Radiol       Date:  2018-09-17       Impact factor: 3.039

Review 2.  The Novel Role of PGC1α in Bone Metabolism.

Authors:  Cinzia Buccoliero; Manuela Dicarlo; Patrizia Pignataro; Francesco Gaccione; Silvia Colucci; Graziana Colaianni; Maria Grano
Journal:  Int J Mol Sci       Date:  2021-04-28       Impact factor: 5.923

3.  Microscale poroelastic metamodel for efficient mesoscale bone remodelling simulations.

Authors:  C C Villette; A T M Phillips
Journal:  Biomech Model Mechanobiol       Date:  2017-08-09

4.  Nonlinear voxel-based finite element model for strength assessment of healthy and metastatic proximal femurs.

Authors:  Amelie Sas; Nicholas Ohs; Esther Tanck; G Harry van Lenthe
Journal:  Bone Rep       Date:  2020-04-01

Review 5.  Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature.

Authors:  Nikolas K Knowles; Jacob M Reeves; Louis M Ferreira
Journal:  J Exp Orthop       Date:  2016-12-09
  5 in total