| Literature DB >> 24007094 |
Jeremy M D Kowalczyk1, Michael R Hadmack, John M J Madey.
Abstract
We describe a simple method to measure the back-bombardment heating temperature rise as a function of time in pulsed microwave thermionic guns using a fast rise-time InGaAs detector and optical pyrometer. Gaining knowledge of the nature of that temperature rise and the corresponding current out of the gun are the first steps in devising a scheme to counteract the back-bombardment heating which lengthens the micropulses, limits the macropulse length, and increases the energy spread of the emitted electron beam. We measured a temperature rise of 59 K in our LaB6 cathode which delivered a peak of 600 mA over a 5 μs RF pulse in our 0.33 MV/cm peak field, 2.856 GHz thermionic electron gun.Year: 2013 PMID: 24007094 DOI: 10.1063/1.4817539
Source DB: PubMed Journal: Rev Sci Instrum ISSN: 0034-6748 Impact factor: 1.523