PURPOSE: To reduce image distortion in MR diffusion imaging using an accelerated multi-shot method. METHODS: The proposed method exploits the fact that diffusion-encoded data tend to be sparse when represented in the kb-kd space, where kb and kd are the Fourier transform duals of b and d, the b-factor and the diffusion direction, respectively. Aliasing artifacts are displaced toward under-used regions of the kb-kd plane, allowing nonaliased signals to be recovered. A main characteristic of the proposed approach is how thoroughly the navigator information gets used during reconstruction: The phase of navigator images is used for motion correction, while the magnitude of the navigator signal in kb-kd space is used for regularization purposes. As opposed to most acceleration methods based on compressed sensing, the proposed method reduces the number of ky lines needed for each diffusion-encoded image, but not the total number of images required. Consequently, it tends to be most effective at reducing image distortion rather than reducing total scan time. RESULTS: Results are presented for three volunteers with acceleration factors ranging from 4 to 8, with and without the inclusion of parallel imaging. CONCLUSION: An accelerated motion-corrected diffusion imaging method was introduced that achieves good image quality at relatively high acceleration factors.
PURPOSE: To reduce image distortion in MR diffusion imaging using an accelerated multi-shot method. METHODS: The proposed method exploits the fact that diffusion-encoded data tend to be sparse when represented in the kb-kd space, where kb and kd are the Fourier transform duals of b and d, the b-factor and the diffusion direction, respectively. Aliasing artifacts are displaced toward under-used regions of the kb-kd plane, allowing nonaliased signals to be recovered. A main characteristic of the proposed approach is how thoroughly the navigator information gets used during reconstruction: The phase of navigator images is used for motion correction, while the magnitude of the navigator signal in kb-kd space is used for regularization purposes. As opposed to most acceleration methods based on compressed sensing, the proposed method reduces the number of ky lines needed for each diffusion-encoded image, but not the total number of images required. Consequently, it tends to be most effective at reducing image distortion rather than reducing total scan time. RESULTS: Results are presented for three volunteers with acceleration factors ranging from 4 to 8, with and without the inclusion of parallel imaging. CONCLUSION: An accelerated motion-corrected diffusion imaging method was introduced that achieves good image quality at relatively high acceleration factors.
Authors: R V Mulkern; H Gudbjartsson; C F Westin; H P Zengingonul; W Gartner; C R Guttmann; R L Robertson; W Kyriakos; R Schwartz; D Holtzman; F A Jolesz; S E Maier Journal: NMR Biomed Date: 1999-02 Impact factor: 4.044
Authors: Van J Wedeen; Patric Hagmann; Wen-Yih Isaac Tseng; Timothy G Reese; Robert M Weisskoff Journal: Magn Reson Med Date: 2005-12 Impact factor: 4.668
Authors: David Atkinson; Serena Counsell; Joseph V Hajnal; Philip G Batchelor; Derek L G Hill; David J Larkman Journal: Magn Reson Med Date: 2006-11 Impact factor: 4.668
Authors: Isaac Daimiel Naranjo; Roberto Lo Gullo; Elizabeth A Morris; Toni Larowin; Maggie M Fung; Arnaud Guidon; Katja Pinker; Sunitha B Thakur Journal: Radiol Imaging Cancer Date: 2020-05-29
Authors: Pelin Aksit Ciris; Jr-Yuan George Chiou; Daniel I Glazer; Tzu-Cheng Chao; Clare M Tempany-Afdhal; Bruno Madore; Stephan E Maier Journal: Invest Radiol Date: 2019-04 Impact factor: 6.016