Literature DB >> 24005005

Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor.

Gulsu Sener1, Erdogan Ozgur, Abbas Yousefi Rad, Lokman Uzun, Ridvan Say, Adil Denizli.   

Abstract

Procalcitonin (PCT) is a promising biomarker for identification of the origin and severity of sepsis, which is a deadly body infection. In this work, we report the preparation of a surface plasmon resonance (SPR) biosensor which utilizes a molecular imprinted polymer surface for rapid and reliable detection of PCT. The molecular imprinted surface was prepared using a microcontact imprinting technique, in which PCT molecules were first immobilized onto a glass support and brought into contact with a solution of 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) on a SPR sensor, then the polymerization process was performed. After removal of the PCT molecules, specific molecular recognition sites were obtained, where PCT molecules can selectively rebind, only at the surface of the polymer matrix. PCT detection studies were carried out using PCT solutions in phosphate buffer and simulated blood plasma (SBP) at different concentrations. The SPR biosensor can detect very low concentrations (9.9 ng mL(-1)) of PCT within approximately 1 h, in both phosphate buffer and SBP. High selectivity of the biosensor against PCT was also demonstrated in the presence of several competitive proteins such as human serum albumin, myoglobin and cytochrome c.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24005005     DOI: 10.1039/c3an00958k

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  17 in total

1.  A facile, sensitive and rapid sensing platform based on CoZnO for detection of fipronil; an environmental toxin.

Authors:  Sanni Kumar; Natalia Vasylieva; Vikrant Singh; Bruce Hammock; Shiv Govind Singh
Journal:  Electroanalysis       Date:  2020-06-18       Impact factor: 3.223

2.  Procalcitonin levels in fresh serum and fresh synovial fluid for the differential diagnosis of knee septic arthritis from rheumatoid arthritis, osteoarthritis and gouty arthritis.

Authors:  Chenggong Wang; DA Zhong; Qiande Liao; Lingyu Kong; Ansong Liu; Han Xiao
Journal:  Exp Ther Med       Date:  2014-07-29       Impact factor: 2.447

Review 3.  MIPs and Aptamers for Recognition of Proteins in Biomimetic Sensing.

Authors:  Marcus Menger; Aysu Yarman; Júlia Erdőssy; Huseyin Bekir Yildiz; Róbert E Gyurcsányi; Frieder W Scheller
Journal:  Biosensors (Basel)       Date:  2016-07-18

Review 4.  Imprinting of Microorganisms for Biosensor Applications.

Authors:  Neslihan Idil; Bo Mattiasson
Journal:  Sensors (Basel)       Date:  2017-03-29       Impact factor: 3.576

5.  Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA.

Authors:  Gizem Ertürk; Dmitriy Berillo; Martin Hedström; Bo Mattiasson
Journal:  Biotechnol Rep (Amst)       Date:  2014-06-25

Review 6.  Molecular Imprinting Applications in Forensic Science.

Authors:  Erkut Yılmaz; Bora Garipcan; Hirak K Patra; Lokman Uzun
Journal:  Sensors (Basel)       Date:  2017-03-28       Impact factor: 3.576

Review 7.  Molecular Imprinting Techniques Used for the Preparation of Biosensors.

Authors:  Gizem Ertürk; Bo Mattiasson
Journal:  Sensors (Basel)       Date:  2017-02-04       Impact factor: 3.576

8.  Magnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis.

Authors:  Águeda Molinero-Fernández; María Moreno-Guzmán; Miguel Ángel López; Alberto Escarpa
Journal:  Biosensors (Basel)       Date:  2020-06-17

Review 9.  Key Enabling Technologies for Point-of-Care Diagnostics.

Authors:  Elisabetta Primiceri; Maria Serena Chiriacò; Francesca M Notarangelo; Antonio Crocamo; Diego Ardissino; Marco Cereda; Alessandro P Bramanti; Marco A Bianchessi; Gianluigi Giannelli; Giuseppe Maruccio
Journal:  Sensors (Basel)       Date:  2018-10-24       Impact factor: 3.576

10.  Establishment of a novel homogeneous nanoparticle-based assay for sensitive procalcitonin detection of ultra low-volume serum samples.

Authors:  Peng Li; Zhenhua Chen; Bing Liu; Kun Li; Hao Wang; Li Lin; Ling He; Jie Wei; Tiancai Liu
Journal:  Int J Nanomedicine       Date:  2018-09-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.