Zichuan Zhang1, Jun Kuang, Lingjun Li. 1. School of Pharmacy, University of Wisconsin, 777 Highland Avenue, Madison, Wisconsin 53705, USA. lli@pharmacy.wisc.edu.
Abstract
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometric imaging (MSI) has been employed as a detection method for both capillary electrophoresis (CE)-MALDI and liquid chromatography (LC)-MALDI analyses. Based on our previous studies, here we report a new interface to couple LC with MSI by employing an automated matrix sprayer. The LC trace is directly collected on a ground stainless steel MALDI plate and dried. The matrix is sprayed on the MALDI plate using a programmable matrix sprayer. With the highly uniform matrix layers produced from the sprayer, the MS image signal quality is significantly improved with enhanced signal-to-noise ratios for analyte peaks. With the programmable matrix application and imaging MS data acquisition, the new LC-MSI platform exhibits highly stable and reproducible performance. A total of 87 bovine serum albumin (BSA) tryptic peptides and 295 putative neuropeptides from blue crab pericardial organs have been observed with LC-MSI analysis, exhibiting better performance in terms of peptide coverage than regular LC-MALDI with discrete spot collection and our previously reported LC-MSI interface with the matrix being delivered by a capillary. In addition to relative quantitation with isotopic labeling as we have previously demonstrated, we performed the first absolute quantitation using the new LC-MSI platform and obtained accurate quantitation results for neuropeptides, indicating great potential for quantitative analysis of complex samples.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometric imaging (MSI) has been employed as a detection method for both capillary electrophoresis (CE)-MALDI and liquid chromatography (LC)-MALDI analyses. Based on our previous studies, here we report a new interface to couple LC with MSI by employing an automated matrix sprayer. The LC trace is directly collected on a ground n class="Chemical">stainless steel MALDI plate and dried. The matrix is sprayed on the MALDI plate using a programmable matrix sprayer. With the highly uniform matrix layers produced from the sprayer, the MS image signal quality is significantly improved with enhanced signal-to-noise ratios for analyte peaks. With the programmable matrix application and imaging MS data acquisition, the new LC-MSI platform exhibits highly stable and reproducible performance. A total of 87 bovine serum albumin (BSA) tryptic peptides and 295 putative neuropeptides from blue crab pericardial organs have been observed with LC-MSI analysis, exhibiting better performance in terms of peptide coverage than regular LC-MALDI with discrete spot collection and our previously reported LC-MSI interface with the matrix being delivered by a capillary. In addition to relative quantitation with isotopic labeling as we have previously demonstrated, we performed the first absolute quantitation using the new LC-MSI platform and obtained accurate quantitation results for neuropeptides, indicating great potential for quantitative analysis of complex samples.
Authors: Tomas Rejtar; Ping Hu; Peter Juhasz; Jennifer M Campbell; Marvin L Vestal; Jan Preisler; Barry L Karger Journal: J Proteome Res Date: 2002 Mar-Apr Impact factor: 4.466
Authors: Ron M A Heeren; Donald F Smith; Jonathan Stauber; Basak Kükrer-Kaletas; Luke MacAleese Journal: J Am Soc Mass Spectrom Date: 2009-03-21 Impact factor: 3.109