Literature DB >> 24002390

Practical experience with the TAG and conformable TAG devices: lessons learned in about 100 cases.

Y Georg1, A Schwein, A Lejay, E Tartaglia, E Girsowicz, J G Kretz, F Thaveau, N Chakfe.   

Abstract

AIM: We reported our 10-year experience with the Gore TAG thoracic endoprosthesis for treatment of thoracic aorta pathologies.
METHODS: We performed a systematic retrospective study of prospectively recorded data of all patients who underwent thoracic endovascular aortic repair (TEVAR) procedure with Gore TAG thoracic endoprosthesis between January 2001 and March 2013, and conducted an analysis of patient demographics, periprocedural records, complications, reinterventions, and survival.
RESULTS: During this period, 96 patients underwent TEVAR with Gore TAG device. Indications for operation were degenerative aneurysm in 38 patients (39.6%), type B aortic dissection in 24 (25.0%), penetrating ulcer in 8 (8.3%), intramural hematoma in 10 (10.4%), traumatic transection in 9 (9.4%), and other pathology in 7 (7.3%). Forty-four patients (45.8%) had acute thoracic aortic syndromes requiring immediate or delayed procedures. Forty-two (43.8%) patients underwent supra-aortic trunks debranching. Landing zones were zone 0 in 8 patients (8.3%), zone 1 in 4 (4.2%), zone 2 in 36 (37.5%), zone 3 in 29 (30.2%) and zone 4 in 19 (19.8%). Technical success rate was 96.6%. Thirty-day mortality was 10.4%. Major adverse events included stroke in 8.3%, spinal cord ischemia in 4.2%, and vascular injuries in 7.3%. Overall survival in the cohort was 86% at 1 year and 78% at 2 years with a mean follow-up of 11.1±12.4 months. Major reintervention was required in 10 patients (10.4%).
CONCLUSION: This single-center study demonstrates acceptable rates for operative mortality and major adverse events after endovascular repair of various thoracic aortic pathologies with both generations of Gore TAG device. However, a better knowledge in long-term results is necessary to define target populations.

Entities:  

Mesh:

Year:  2013        PMID: 24002390

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  3 in total

1.  Best surgical option for arch extension of type B dissection: the endovascular approach.

Authors:  Toru Kuratani
Journal:  Ann Cardiothorac Surg       Date:  2014-05

2.  Device Conformability and Morphological Assessment After TEVAR for Aortic Type B Dissection: A Single-Centre Experience with a Conformable Thoracic Stent-Graft Design.

Authors:  Moritz S Bischoff; Matthias Müller-Eschner; Katrin Meisenbacher; Andreas S Peters; Dittmar Böckler
Journal:  Med Sci Monit Basic Res       Date:  2015-12-31

3.  KNOW-KT (KoreaN cohort study for outcome in patients with kidney transplantation: a 9-year longitudinal cohort study): study rationale and methodology.

Authors:  Jaeseok Yang; Joongyup Lee; Kyu Ha Huh; Jae Berm Park; Jang-Hee Cho; Sik Lee; Han Ro; Seung-Yeup Han; Young Hoon Kim; Jong Cheol Jeong; Byung-Joo Park; Duck Jong Han; Sung-Bae Park; Wookyung Chung; Sung Kwang Park; Chan-Duck Kim; Sung Joo Kim; Yu Seun Kim; Curie Ahn
Journal:  BMC Nephrol       Date:  2014-05-09       Impact factor: 2.388

  3 in total