| Literature DB >> 24001853 |
Tiantian Liu1, Peng Cao, Jinpei Geng, Jinqiang Li, Mingzhen Wang, Minglin Wang, Xiaoyu Li, Dalu Yin.
Abstract
High-performance liquid chromatography with UV detection was used to detect four triazines in milk. An efficient pretreatment method known as cloud point extraction (CPE) was proposed for extracting and preconcentrating analytes. The parameters of CPE including surfactant type and concentration, electrolyte, sample pH, incubation temperature and duration were investigated. Under optimal conditions, satisfying recoveries in the range of 70.5-96.9% were achieved for four triazines. The limits of detection ranged from 6.79 to 11.19μg L(-1). The linear range of quantitation for the four triazines was 50-2000μg L(-1), and the correlation coefficients of the calibration curves were all 0.9999. The results demonstrated that the proposed method was efficient and reliable for the determination of triazine herbicides in milk samples.Entities:
Keywords: Cloud point extraction; HPLC-UV; Milk; Triazines
Mesh:
Substances:
Year: 2013 PMID: 24001853 DOI: 10.1016/j.foodchem.2013.07.062
Source DB: PubMed Journal: Food Chem ISSN: 0308-8146 Impact factor: 7.514