Literature DB >> 2400121

Efficiency of airway heat and moisture exchangers in anesthetized humans.

P E Bickler1, D I Sessler.   

Abstract

The efficiencies of airway heat and moisture exchanging filters in reducing respiratory water losses and increasing airway temperatures during general anesthesia were studied in five tracheally intubated patients given isoflurane, nitrous oxide, and oxygen anesthesia during controlled ventilation. Filters (Humid-Vent Filter, Humid-Vent 1, Pall Conserve, Siemens 150, and ThermoVent 600) were placed between the Y-piece of the anesthesia circle system and the endotracheal tube for 40 min each. Airway temperature, esophageal temperature, and water loss (determined by weighing expired water collected in CaSO4) were measured every 10 min. All of the filters reached near-maximum efficiency in reducing water losses within 10 min. The Humid-Vent Filter and Siemens 150 filters were most efficient, the Pall Conserve and ThermoVent 600 less efficient. Airway temperature rapidly increased 2 degrees-8 degrees C during each trial. The more efficient the filter in conserving water, the greater the airway temperature. The respiratory heat conserved by these filters represents 5.5%-7.2% of the estimated total metabolic heat production during anesthesia in adults.

Entities:  

Mesh:

Year:  1990        PMID: 2400121

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  9 in total

1.  Effects of a circulating-water garment and forced-air warming on body heat content and core temperature.

Authors:  Akiko Taguchi; Jebadurai Ratnaraj; Barbara Kabon; Neeru Sharma; Rainer Lenhardt; Daniel I Sessler; Andrea Kurz
Journal:  Anesthesiology       Date:  2004-05       Impact factor: 7.892

2.  Effects of surgical site and inspired gas warming devices on body temperature during lower abdominal and thoracic surgery.

Authors:  T Harioka; T Sone; K Nomura; M Kakuyama
Journal:  J Anesth       Date:  1992-10       Impact factor: 2.078

3.  Hypothermia induced by laparoscopic insufflation. A randomized study in a pig model.

Authors:  J R Bessell; A Karatassas; J R Patterson; G G Jamieson; G J Maddern
Journal:  Surg Endosc       Date:  1995-07       Impact factor: 4.584

4.  Cutaneous heat loss with three surgical drapes, one impervious to moisture.

Authors:  Paul E Maglinger; Daniel I Sessler; Rainer Lenhardt
Journal:  Anesth Analg       Date:  2005-03       Impact factor: 6.627

5.  Effect of irrigation fluid temperature on body temperature during arthroscopic elbow surgery in dogs.

Authors:  K R Thompson; P D MacFarlane
Journal:  Open Vet J       Date:  2013-10-19

6.  The effect of humidified heated breathing circuit on core body temperature in perioperative hypothermia during thyroid surgery.

Authors:  Hue Jung Park; Ho Sik Moon; Se Ho Moon; Hyeon Do Jeong; Young Jae Jeon; Keung Do Han; Hyun Jung Koh
Journal:  Int J Med Sci       Date:  2017-07-18       Impact factor: 3.738

7.  Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials.

Authors:  Yoon Ji Choi; Sam Hong Min; Jeong Jun Park; Jang Eun Cho; Seung Zhoo Yoon; Suk Min Yoon
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

8.  The Humidity in a Low-Flow Dräger Fabius Anesthesia Workstation with or without Thermal Insulation or a Heat and Moisture Exchanger: A Prospective Randomized Clinical Trial.

Authors:  Sergius A R de Oliveira; Lorena M C Lucio; Norma S P Modolo; Yoko Hayashi; Mariana G Braz; Lídia R de Carvalho; Leandro G Braz; José Reinaldo C Braz
Journal:  PLoS One       Date:  2017-01-27       Impact factor: 3.240

Review 9.  Nasal high flow treatment in preterm infants.

Authors:  Calum T Roberts; Kate A Hodgson
Journal:  Matern Health Neonatol Perinatol       Date:  2017-09-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.