Literature DB >> 24000803

Microfabricated glow discharge plasma (MFGDP) for ambient desorption/ionization mass spectrometry.

Xuelu Ding1, Xuefang Zhan, Xin Yuan, Zhongjun Zhao, Yixiang Duan.   

Abstract

A novel ambient ionization technique for mass spectrometry, microfabricated glow discharge plasma (MFGDP), is reported. This device is made of a millimeter-sized ceramic cavity with two platinum electrodes positioned face-to-face. He or Ar plasma can be generated by a direct current voltage of several hundreds of volts requiring a total power below 4 W. The thermal plume temperature of the He plasma was measured and found to be between 25 and 80 °C at a normal discharge current. Gaseous, liquid, creamy, and solid samples with molecular weights up to 1.5 kDa could be examined in both positive and negative mode, giving limits of detection (LOD) at or below the fg/mm(2) level. The relative standard deviation (RSD) of manual sampling ranged from 10% to ~20%, while correlation coefficients of the working curve (R(2)) are all above 0.98 with the addition of internal standards. The ionization mechanisms are examed via both optical and mass spectrometry. Due to the low temperature characteristics of the microplasma, nonthermal momentum desorption is considered to dominate the desorption process.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24000803     DOI: 10.1021/ac401359k

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Extractive Atmospheric Pressure Photoionization (EAPPI) Mass Spectrometry: Rapid Analysis of Chemicals in Complex Matrices.

Authors:  Chengyuan Liu; Jiuzhong Yang; Jian Wang; Yonghua Hu; Wan Zhao; Zhongyue Zhou; Fei Qi; Yang Pan
Journal:  J Am Soc Mass Spectrom       Date:  2016-07-26       Impact factor: 3.109

2.  Chip-based ingroove microplasma with orthogonal signal collection: new approach for carbon-containing species detection through open air reaction for performance enhancement.

Authors:  Fanying Meng; Xuemei Li; Yixiang Duan
Journal:  Sci Rep       Date:  2014-04-25       Impact factor: 4.379

3.  An Integrated Microfabricated Chip with Double Functions as an Ion Source and Air Pump Based on LIGA Technology.

Authors:  Hua Li; Linxiu Jiang; Chaoqun Guo; Jianmin Zhu; Yongrong Jiang; Zhencheng Chen
Journal:  Sensors (Basel)       Date:  2017-01-04       Impact factor: 3.576

4.  Matrix-Assisted Plasma Atomization Emission Spectrometry for Surface Sampling Elemental Analysis.

Authors:  Xin Yuan; Xuefang Zhan; Xuemei Li; Zhongjun Zhao; Yixiang Duan
Journal:  Sci Rep       Date:  2016-01-14       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.