Literature DB >> 24000742

Comparison of 3M Petrifilm Aerobic Count Plates to standard plating methodology for use with AOAC antimicrobial efficacy methods 955.14, 955.15, 964.02, and 966.04 as an alternative enumeration procedure: collaborative study.

Maria T Nelson1, Robert A LaBudde, Stephen F Tomasino, Rebecca M Pines.   

Abstract

A multilaboratory study was conducted to determine the equivalence of the 3M Petrifilm Aerobic Count Plate and standard plating methodology for measuring viable bacteria and spores recovered from hard-surface carriers (stainless steel and porcelain), also known as "control carrier counts," used in AOAC antimicrobial efficacy test methods. Six laboratories participated in the study in which carriers inoculated with Staphylococcus aureus, Pseudomonas aeruginosa, Salmonella enterica, and spores of Bacillus subtilis were evaluated using 3M Petrifilm Aerobic Count (AC) plates and standard plating side-by-side. The data were analyzed using a matched-pair t-test to determine the between-method effect with confidence intervals. For all test organisms pooled across all laboratories, the mean difference in log10 concentration between the standard plate count method and 3M Petrifilm AC Plates was -0.012, with a 95% confidence interval of (-0.090, +0.066), which was well within the -0.5, +0.5 interval established as the acceptance criterion. The between-carrier SD averaged 0.139; the between-replicate SD was 0.050. The carrier reproducibility, given that a single replicate per carrier is done, was estimated to be 0.148. Although differences were seen in the final concentrations of the test organisms among laboratories, there were no statistical differences between the enumeration methods. Based on the results from this study, 3M Petrifilm AC Plates are equivalent to standard plating methodology and can be used as an alternative procedure for the enumeration of test organisms used in AOAC Methods 955.14, 955.15, 964.02, and 966.04.

Entities:  

Mesh:

Year:  2013        PMID: 24000742     DOI: 10.5740/jaoacint.12-469

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  4 in total

1.  Evaluation of Petrifilm™ aerobic count plates as an equivalent alternative to drop plating on R2A agar plates in a biofilm disinfectant efficacy test.

Authors:  B G Fritz; D K Walker; D E Goveia; A E Parker; D M Goeres
Journal:  Curr Microbiol       Date:  2014-12-04       Impact factor: 2.188

2.  Gnotobiotic Human Colon Ex Vivo.

Authors:  Frank D McDermott; David M A Folan; Des C Winter; Michael A Folan; Alan W Baird
Journal:  Gastroenterology Res       Date:  2015-10-21

3.  Molecular Characterization of Bacteria, Detection of Enterotoxin Genes, and Screening of Antibiotic Susceptibility Patterns in Traditionally Processed Meat Products of Sikkim, India.

Authors:  Meera Ongmu Bhutia; Namrata Thapa; Jyoti Prakash Tamang
Journal:  Front Microbiol       Date:  2021-01-11       Impact factor: 5.640

4.  Interlaboratory study for the evaluation of three microtiter plate-based biofilm quantification methods.

Authors:  Jontana Allkja; Frits van Charante; Juliana Aizawa; Inés Reigada; Clara Guarch-Pérez; Jesus Augusto Vazquez-Rodriguez; Paul Cos; Tom Coenye; Adyary Fallarero; Sebastian A J Zaat; Antonio Felici; Livia Ferrari; Nuno F Azevedo; Albert E Parker; Darla M Goeres
Journal:  Sci Rep       Date:  2021-07-02       Impact factor: 4.379

  4 in total