Comparison of the diagnostic quality of computed tomography images of normal ocular and orbital structures acquired with and without the use of general anesthesia in the cat.

Sean P Collins1, Jodi S Matheson, Ralph E Hamor, Mark A Mitchell, Amber L Labelle, Robert T O'Brien.   

Abstract

OBJECTIVE: To compare the diagnostic quality of computed tomography (CT) images of normal ocular and orbital structures acquired with and without the use of general anesthesia in the cat. ANIMAL STUDIED: Eleven privately owned cats with nasal disease presenting to a single referral hospital. PROCEDURES: All cats received a complete ophthalmic examination. A 16 multislice helical CT system was utilized to acquire images of the skull and neck with and without the use of general anesthesia. Images were acquired before and after the administration of intravenous iodinated contrast. Images of normal ocular and orbital structures were evaluated via consensus by two board-certified radiologists. Visibility of ocular and orbital structures, degree of motion, and streak artifact were assessed and scored for each image set in the transverse, dorsal, and sagittal planes.
RESULTS: The use of general anesthesia did not significantly affect the diagnostic quality of images. No motion artifact was observed in any CT image. Streak artifact was significantly increased in scans performed in the transverse orientation but not in the dorsal orientation or sagittal orientation and did not affect the diagnostic quality of the images. Contrast enhancement did not significantly enhance the visibility of any ocular or orbital structures.
CONCLUSION: Diagnostic CT images of normal ocular and orbital structures can be acquired without the use of general anesthesia in the cat.
© 2012 American College of Veterinary Ophthalmologists.

Entities:  

Keywords:  VetMouseTrap™; anesthesia; computed tomography; eye; feline; orbit

Mesh:

Year:  2012        PMID: 23998509     DOI: 10.1111/vop.12005

Source DB:  PubMed          Journal:  Vet Ophthalmol        ISSN: 1463-5216            Impact factor:   1.644


  2 in total

1.  Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study.

Authors:  A Cirla; M Rondena; G Bertolini
Journal:  Open Vet J       Date:  2016-07-21

2.  Intra-arterial versus intra venous contrast-enhanced computed tomography of the equine head.

Authors:  Casper P Crijns; Yseult Baeumlin; Lieve De Rycke; Bart J G Broeckx; Lieven Vlaminck; Erik H J Bergman; Henri van Bree; Ingrid Gielen
Journal:  BMC Vet Res       Date:  2016-01-07       Impact factor: 2.741

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.