Literature DB >> 23998507

Determining cutting efficiency of nickel-titanium coronal flaring instruments used in lateral action.

O A Peters1, R D Morgental, K A Schulze, F Paqué, P M P Kopper, F V Vier-Pelisser.   

Abstract

AIM: To develop a method to evaluate the cutting behaviour of nickel-titanium (NiTi) coronal flaring instruments.
METHODOLOGY: BioRaCe BR0 (BR), HyFlex CM 1 (HY), ProFile OS No. 2 (PF) and ProTaper Sx (PT) instruments were used in simulated coronal flaring using a lateral action against bovine dentine blocks, at 250 and 500 rpm. Cutting efficiency was assessed by three methods: first, areas of notches produced by instruments were directly measured under a stereomicroscope. Second, dentine specimens were then analysed by surface profilometry to determine the maximum cutting depth and finally by microcomputed tomography to assess the volume of removed dentine. Data were compared using parametric tests with the significance level set at 0.05.
RESULTS: For all three methods, HY and PF were the most and the least cutting-efficient instruments, respectively (P < 0.05). Significant differences were detected between 250 and 500 rpm for HY and PT (area); for BR, HY and PT (depth); and for BR and HY (volume). There were strong positive correlations between the results obtained with those three different methods with r-values ranging from 0.81 to 0.92.
CONCLUSION: Measuring the amount of material removed in a specific time under stereomicroscopy is a simple and rational way to assess the cutting behaviour of NiTi rotary instruments in lateral action. HyFlex, manufactured with thermomechanically treated NiTi wire, was the most efficient instrument, and increased rotational speed was associated with increased cutting efficiency.
© 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  coronal flaring; cutting efficiency; endodontics; nickel-titanium alloy; root canal preparation; rotational speed

Mesh:

Substances:

Year:  2013        PMID: 23998507     DOI: 10.1111/iej.12177

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  13 in total

1.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

2.  "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.

Authors:  N Tulasi Priya; Veeramachaneni Chandrasekhar; S Anita; Muralidhar Tummala; T B Phanindhar Raj; Vijetha Badami; Pradeep Kumar; E Soujanya
Journal:  J Clin Diagn Res       Date:  2014-12-05

3.  Reciproc and Reciproc Blue in the removal of bioceramic and resin-based sealers in retreatment procedures.

Authors:  Kaline Romeiro; Andressa de Almeida; Marcely Cassimiro; Luciana Gominho; Eugênia Dantas; Nayane Chagas; Christianne Velozo; Laila Freire; Diana Albuquerque
Journal:  Clin Oral Investig       Date:  2019-05-18       Impact factor: 3.573

4.  Effect of instrument speed when used in reciprocating motion on root canal transportation and centering ability.

Authors:  Ezgi Doganay Yildiz; Hakan Arslan; Meltem Sumbullu; Ibrahim Sevki Bayrakdar; Muhammed Akif Sumbullu; Ertugrul Karatas
Journal:  J Conserv Dent       Date:  2017 Jul-Aug

5.  Comparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM.

Authors:  Sanjib Das; Prasanti Kumari Pradhan; S Lata; Sachidananda Prasad Sinha
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

6.  Resistance to fracture of teeth instrumented using novel EndoStar E5 rotary versus ProTaper NEXT and WaveOne file systems.

Authors:  Ajinkya M Pawar; Mansing G Pawar; Bhagyashree Thakur; Kulwinder Singh Banga; Alexander Maniangat Luke
Journal:  J Conserv Dent       Date:  2018 Jan-Feb

Review 7.  Nickel-Titanium Rotary File Systems: What's New?

Authors:  Sadia Tabassum; Kamil Zafar; Fahad Umer
Journal:  Eur Endod J       Date:  2019-10-18

8.  Microscopic Assessment of Dentinal Defects Induced by ProTaper Universal, ProTaper Gold, and Hyflex Electric Discharge Machining Rotary File Systems - An in vitro Study.

Authors:  Takhellambam Premlata Devi; Amandeep Kaur; Shamurailatpam Priyadarshini; B S Deepak; Sumita Banerjee; Ng Sanjeeta
Journal:  Contemp Clin Dent       Date:  2021-09-21

9.  Vertical root fracture resistance and dentinal crack formation of root canal-treated teeth instrumented with different nickel-titanium rotary systems: an in-vitro study.

Authors:  Galvin Sim Siang Lin; Kiran Prabhakar Singbal; Tahir Yusuf Noorani; Raghavendra Penukonda
Journal:  Odontology       Date:  2021-07-16       Impact factor: 2.634

10.  A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study.

Authors:  Fauzia Ashraf; Pushpa Shankarappa; Abhinav Misra; Asheesh Sawhney; Nandamuri Sridevi; Anu Singh
Journal:  Scientifica (Cairo)       Date:  2016-06-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.