Literature DB >> 23994455

Spatio-temporal pharmacokinetic model based registration of 4D PET neuroimaging data.

Jieqing Jiao1, Graham E Searle, Andri C Tziortzi, Cristian A Salinas, Roger N Gunn, Julia A Schnabel.   

Abstract

In dynamic positron emission tomography (PET) neuroimaging studies, where scan durations often exceed 1h, registration of motion-corrupted dynamic PET images is necessary in order to maintain the integrity of the physiological, pharmacological, or biochemical information derived from the tracer kinetic analysis of the scan. In this work, we incorporate a pharmacokinetic model, which is traditionally used to analyse PET data following any registration, into the registration process itself in order to allow for a groupwise registration of the temporal time frames. The new method is shown to achieve smaller registration errors and improved kinetic parameter estimates on validation data sets when compared with image similarity based registration approaches. When applied to measured clinical data from 10 healthy subjects scanned with [(11)C]-(+)-PHNO (a dopamine D3/D2 receptor tracer), it reduces the intra-class variability on the receptor binding outcome measure, further supporting the improvements in registration accuracy. Our method incorporates a generic tracer kinetic model which makes it applicable to different PET radiotracers to remove motion artefacts and increase the integrity of dynamic PET studies.
© 2013.

Entities:  

Keywords:  Motion correction; Neuroreceptor imaging; PET; Pharmacokinetic modelling; Spatio-temporal registration

Mesh:

Substances:

Year:  2013        PMID: 23994455     DOI: 10.1016/j.neuroimage.2013.08.031

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  3 in total

Review 1.  Artificial Intelligence in Lymphoma PET Imaging:: A Scoping Review (Current Trends and Future Directions).

Authors:  Navid Hasani; Sriram S Paravastu; Faraz Farhadi; Fereshteh Yousefirizi; Michael A Morris; Arman Rahmim; Mark Roschewski; Ronald M Summers; Babak Saboury
Journal:  PET Clin       Date:  2022-01

2.  Impact of image-based motion correction on dopamine D3/D2 receptor occupancy-comparison of groupwise and frame-by-frame registration approaches.

Authors:  Jieqing Jiao; Graham E Searle; Julia A Schnabel; Roger N Gunn
Journal:  EJNMMI Phys       Date:  2015-07-29

3.  Motion correction of free-breathing magnetic resonance renography using model-driven registration.

Authors:  Dimitra Flouri; Daniel Lesnic; Constantina Chrysochou; Jehill Parikh; Peter Thelwall; Neil Sheerin; Philip A Kalra; David L Buckley; Steven P Sourbron
Journal:  MAGMA       Date:  2021-06-23       Impact factor: 2.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.