Literature DB >> 23993053

Comparison of fixation methods after anteromedialization osteotomy of the tibial tubercle for patellar instability.

Brent T Warner1, Ganesh V Kamath, Jeffrey T Spang, Paul S Weinhold, R Alexander Creighton.   

Abstract

PURPOSE: The aim of this study was to evaluate the biomechanical strength of two 4.5-mm screws and three 3.5-mm screws for fixation of the tibial tubercle after anteromedialization osteotomy.
METHODS: Anteromedialization of the tibial tubercle was performed on 5 pairs of fresh-frozen cadaveric lower extremities. One leg from each pair was randomized to fixation with two 4.5-mm screws and the contralateral leg to fixation with three 3.5-mm screws. Each specimen was loaded cyclically to simulate an active straight-leg raise and then to failure while displacement of the tubercle fragment was recorded.
RESULTS: There was no difference in mean tubercle fragment displacement under cyclic loading at any cycle number (P > .352). Maximum failure load for osteotomies secured with two 4.5-mm screws was 1,459 ± 540 N, and for three 3.5-mm screws it was 1,360 ± 707 N. This was not a statistically significant difference (P = .723). Tubercle migration of 7 mm was chosen as clinical failure. At this amount of displacement, mean load was 1,085 ± 398 N and 764 ± 313 N in the 4.5-mm and 3.5-mm groups, respectively, which was also not significantly different (P = .146).
CONCLUSIONS: Both 2 × 4.5-mm and 3 × 3.5-mm screw constructs after tibial tubercle anteromedialization are equally capable of withstanding physiologic forces like those encountered during an active straight-leg raise and have similar failure strength. CLINICAL RELEVANCE: Although both configurations are comparable, the use of the smaller 3.5-mm screws may reduce the need for hardware removal related to prominence and soft tissue irritation.
Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23993053     DOI: 10.1016/j.arthro.2013.06.020

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  3 in total

1.  Modified Technique of Tibial Tuberosity Transfer.

Authors:  Gopalakrishna Pemmaraju; Abbas Raad; Amit Kotecha; Sanjiv Chugh; Ejaz Mughal
Journal:  Arthrosc Tech       Date:  2015-08-10

2.  Suture Tape Augmentation of Screw Fixation Reduces Fragment Migration in Tibial Tubercle Osteotomy: A Biomechanical Study.

Authors:  Mark Frame; Oliver Hauck; Michael Newman; Anna Cirtautas; Coen Wijdicks
Journal:  Orthop J Sports Med       Date:  2021-10-01

3.  Bioabsorbable magnesium screw fixation for tibial tubercle osteotomy; a preliminary study.

Authors:  Melih Ünal; Engin Demirayak; Mehmet Baris Ertan; Omer Faruk Kilicaslan; Ozkan Kose
Journal:  Acta Biomed       Date:  2022-01-19
  3 in total