Literature DB >> 23991637

The impact of transvenous lead extraction on tricuspid valve function.

James O Coffey1, Solomon J Sager, Sandeep Gangireddy, Avi Levine, Juan F Viles-Gonzalez, Avi Fischer.   

Abstract

BACKGROUND: Few data exist regarding the effect of transvenous lead extraction (TLE) on tricuspid valve function. The objective of this study was to examine the effect of TLE on the development of postprocedure tricuspid regurgitation (TR).
OBJECTIVE: To assess the impact of TLE on tricuspid valve function.
METHODS: A single center retrospective analysis of consecutive patients referred for TLE between June 2006 and November 2011. Patients were included only if they underwent transthoracic echocardiography (TTE) before and after lead extraction (N = 124). Patients were assigned a preprocedure and postprocedure TR score on a continuous scale from 0 to 6 (0 = none, 1 = trace, 2 = mild, 3 = mild/moderate, 4 = moderate, 5 = moderate/severe, and 6 = severe). A clinically significant increase in TR was defined as both (1) an increase in TR score of at least two points, and (2) a postprocedure TR score ≥4 (moderate).
RESULTS: A total of 124 patients referred for TLE underwent a TTE both before (9 ±16 months) and after lead extraction (4 ± 8 months). A total of 200 leads (1.6 ± 0.8 per patient) were extracted. The mean change in TR score after lead extraction was +0.18 (95% confidence interval [CI] -0.03 to 0.39, P = 0.11). A clinically significant increase in TR occurred in 7/124 (5.6% [CI 2.3-11.3%]) patients. Age ≥75 (+0.45, [CI 0.07-0.84, P = 0.02]), removal of ≥2 leads (+0.40 [CI 0-0.81, P = 0.05]), and powered sheath-assisted extraction (+0.34 [CI 0.05-0.62, P = 0.02]) were significantly associated with an increase in TR score.
CONCLUSION: TLE is rarely associated with the development of clinically significant TR. In our cohort, patient age ≥75 years, pacemaker as opposed to ICD, and removal of ≥2 leads predicted worsening TR. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  cardiac implantable electronic device; device infection; device malfunction; lead extraction; tricuspid regurgitation; valvular heart disease

Mesh:

Year:  2013        PMID: 23991637     DOI: 10.1111/pace.12236

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  6 in total

1.  The role of cardiac surgery in transvenous lead extraction. A high-volume center experience with 3207 procedures.

Authors:  Łukasz Tułecki; Marek Czajkowski; Sylwia Targońska; Konrad Tomków; Dorota Nowosielecka; Wojciech Jacheć; Anna Polewczyk; Andrzej Kutarski
Journal:  Kardiochir Torakochirurgia Pol       Date:  2022-10-08

2.  The prognostic value of transesophageal echocardiography after transvenous lead extraction: landscape after battle.

Authors:  Dorota Nowosielecka; Wojciech Jacheć; Anna Polewczyk; Andrzej Kleinrok; Łukasz Tułecki; Andrzej Kutarski
Journal:  Cardiovasc Diagn Ther       Date:  2021-04

3.  Case report: Pacemaker lead perforation of a papillary muscle inducing severe tricuspid regurgitation.

Authors:  Martin Andreas; Franz Gremmel; Andreas Habertheuer; Claus Rath; Claudia Oeser; Cesar Khazen; Alfred Kocher
Journal:  J Cardiothorac Surg       Date:  2015-03-25       Impact factor: 1.637

4.  Transvenous lead extraction using the TightRail mechanical rotating dilator sheath for Asian patients.

Authors:  Ji-Hoon Choi; Seung-Jung Park; Hye Ree Kim; Hee-Jin Kwon; Kyoung-Min Park; Young Keun On; June Soo Kim; Ju Youn Kim; Won Young Jung
Journal:  Sci Rep       Date:  2022-01-17       Impact factor: 4.379

5.  Analysis of Risk Factors for Major Complications of 1500 Transvenous Lead Extraction Procedures with Especial Attention to Tricuspid Valve Damage.

Authors:  Łukasz Tułecki; Anna Polewczyk; Wojciech Jacheć; Dorota Nowosielecka; Konrad Tomków; Paweł Stefańczyk; Jarosław Kosior; Krzysztof Duda; Maciej Polewczyk; Andrzej Kutarski
Journal:  Int J Environ Res Public Health       Date:  2021-08-28       Impact factor: 3.390

6.  Tricuspid Valve Damage Related to Transvenous Lead Extraction.

Authors:  Anna Polewczyk; Wojciech Jacheć; Dorota Nowosielecka; Andrzej Tomaszewski; Wojciech Brzozowski; Dorota Szczęśniak-Stańczyk; Krzysztof Duda; Andrzej Kutarski
Journal:  Int J Environ Res Public Health       Date:  2022-09-27       Impact factor: 4.614

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.