Literature DB >> 23990191

Transcatheter closure of atrial septal defect in children up to 10 kg of body weight with Amplatzer device.

Mateusz Knop, Małgorzata Szkutnik, Roland Fiszer, Beata Białkowska, Jan Głowacki, Jacek Białkowski1.   

Abstract

BACKGROUND: Transcatheter closure of atrial septal defect (ASD) in older children and adults is currently considered the first-choice therapeutic option. This approach remains challenging in younger children. The aim of the study was to evaluate feasibility, safety and midterm efficacy of percutaneous ASD closure in symptomatic infants ≤10 kg body weight in our institution.
METHODS: There were 28 children up to 10 kg of body weight, who were qualified for transcatheter closure of ASD. All patients but one showed overload of right atrium and right ventricle. Mean weight of patients who underwent transcatheter closure was 9.2 ± 0.88 kg and age 1.59 ± 0.58 years, respectively. Transcatheter closure of ASD was conducted using Amplatzer occluders (ASO).
RESULTS: The devices were implanted successfully in 26/28 patients (93%). In 2 (7%) children the device repeatedly straddled the septum in relatively big ASD and the procedure was abandoned. Mean ASD diameter in patients, who underwent transcatheter closure, was 9.08 ± 2.9 mm (transthoracic echocardiography) and mean implant size/weight ratio was 1.07 ± 0.31. In the child with right-left shunt through ASD normalization of saturation occurred. Mean fluoroscopy time was 4.16 min. In 3 children minor complications occurred: transient arrhythmias (n = 1), fever after procedure (n = 2). The follow-up time was 6.1 (range 1.2-11) years. At follow-up, clinical condition and/or growth improved in all patients except 4 children with coexisting comorbidity. No arrhythmia nor conduction disturbances were observed during follow-up.
CONCLUSIONS: In selected patients weighing less or equal to 10 kg, percutaneous closure of ASD is a safe and effective procedure.

Entities:  

Mesh:

Year:  2013        PMID: 23990191     DOI: 10.5603/CJ.a2013.0120

Source DB:  PubMed          Journal:  Cardiol J        ISSN: 1898-018X            Impact factor:   2.737


  8 in total

1.  Transcatheter Closure of Atrial Septal Defects using the GORE(®) Septal Occluder in Children Less Than 10 kg of Body Weight.

Authors:  Tariq Abu-Tair; Christiane M Wiethoff; Jascha Kehr; Wlodzimierz Kuroczynski; Christoph Kampmann
Journal:  Pediatr Cardiol       Date:  2016-02-19       Impact factor: 1.655

2.  Early Complications After Percutaneous Closure of Atrial Septal Defect in Infants with Procedural Weight Less than 15 kg.

Authors:  Gustaf Tanghöj; Michal Odermarsky; Estelle Naumburg; Petru Liuba
Journal:  Pediatr Cardiol       Date:  2016-11-11       Impact factor: 1.655

3.  The efficacy and safety of using amplatzer for transcatheter closure of atrial septal defect in small children with less than 10 kg.

Authors:  Mehdi Ghaderian; Mohammad Reza Sabri; Ali Reza Ahmadi; Bahar Dehghan; Chehre Mahdavi; Zakie Zahra Ataei
Journal:  ARYA Atheroscler       Date:  2019-01

4.  Transesophageal echocardiography and fluoroscopy for percutaneous closure of atrial septal defects: A comparative study.

Authors:  Weize Xu; Jianhua Li; Jingjing Ye; Jin Yu; Jiangen Yu; Zewei Zhang
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

5.  Transcatheter closure of atrial septal defect in symptomatic children weighing ≤10 kg: Addressing unanswered issues from a decade of experience.

Authors:  Bharti Sharma; Robin Pinto; Bharat Dalvi
Journal:  Ann Pediatr Cardiol       Date:  2019-12-04

6.  Alternative hybrid and staged interventional treatment of congenital heart defects in critically ill children with complex and non-cardiac problems.

Authors:  Ireneusz Haponiuk; Maciej Chojnicki; Radosław Jaworski; Mariusz Steffens; Aneta Szofer-Sendrowska; Konrad Paczkowski; Ewelina Kwaśniak; Jacek Zieliński; Katarzyna Gierat-Haponiuk; Katarzyna Leszczyńska
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2015-02-25       Impact factor: 1.195

7.  Spontaneous closure of a large atrial septal defect in an infant.

Authors:  Roland Fiszer; Małgorzata Szkutnik; Beata Chodór; Jacek Białkowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2014-11-17       Impact factor: 1.426

8.  Hybrid muscular ventricular septal defect closure in a 4.5 kg infant followed by sildenafil treatment and transcatheter atrial septal defect occlusion.

Authors:  Michal Galeczka; Roland Fiszer; Szymon Pawlak; Joanna Sliwka; Linda Litwin; Malgorzata Szkutnik
Journal:  Postepy Kardiol Interwencyjnej       Date:  2018-03-22       Impact factor: 1.426

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.