Brenda Valenzuela-Alcaraz1, Fàtima Crispi, Bart Bijnens, Monica Cruz-Lemini, Montserrat Creus, Marta Sitges, Joaquim Bartrons, Salvadora Civico, Juan Balasch, Eduard Gratacós. 1. Institut Clínic de Ginecologia, Obstetrícia i Neonatologia, Hospital Clinic, Fetal and Perinatal Medicine Research Group (B.V.-A., F.C., M.C.-L., M.C., S.C., J. Balasch, E.G.) and Cardiology Department, Thorax Institute, Hospital Clínic (M.S.), Institut d'Investigacions Biomèdiques August Pi i Sunyer, University of Barcelona, Barcelona, Spain; Centro de Investigación Biomédica en Red en Enfermedades Raras, Barcelona, Spain (F.C., E.G.); Institució Catalana de Recerca i Estudis Avançats, Universitat Pompeu Fabra, Barcelona, Spain (B.B.); and Department of Pediatric Cardiovascular Surgery, University Hospital Sant Joan de Déu, Esplugues de Llobregat, Barcelona, Spain (J. Bartrons).
Abstract
BACKGROUND: Assisted reproductive technologies (ARTs) have been shown to be associated with general vascular dysfunction in late childhood. However, it is unknown whether cardiac remodeling is also present and if these changes already manifest in prenatal life. Our aim was to assess fetal and infant (6 months of age) cardiovascular function in ART pregnancies. METHODS AND RESULTS: This prospective cohort study included 100 fetuses conceived by ART and 100 control pregnancies. ART fetuses showed signs of cardiovascular remodeling, including a more globular heart with thicker myocardial walls, decreased longitudinal function (tricuspid ring displacement in controls: median, 6.5 mm [interquartile range, 6.1-7.1 mm]; tricuspid ring displacement in ART: 5.5 mm [interquartile range, 5.1-6.1]; P<0.001), impaired relaxation, and dilated atria (atrial area in controls, 1.46 cm(2) [interquartile range, 1.2-1.5 cm(2)]; atrial area in ART, 1.6 cm(2) [interquartile range, 1.3-1.8 cm(2)]; P<0.001). Additionally, ART infants showed persistence of most cardiac changes and a significant increase in blood pressure and aortic intima-media thickness (systolic blood pressure in controls, 74 mm Hg [interquartile range, 67-83 mm Hg]; systolic blood pressure in ART, 83 mm Hg [interquartile range, 75-94 mm Hg]; P<0.001; aortic intima-media thickness in controls, 0.52 mm [interquartile range, 0.45-0.56 mm]; aortic intima-media thickness in ART, 0.64 mm [interquartile range, 0.62-0.67]; P<0.001). We could not demonstrate that our findings were directly caused by ART because of their association with various confounding factors, including intrauterine growth restriction or factors related to the cause of infertility. CONCLUSIONS: Children conceived by ART manifest cardiac and vascular remodeling that is present in fetal life and persists in postnatal life, suggesting opportunities for early detection and potential intervention. The underlying mechanisms and the effect of potential confounders such as growth restriction or prematurity remain to be elucidated.
BACKGROUND: Assisted reproductive technologies (ARTs) have been shown to be associated with general vascular dysfunction in late childhood. However, it is unknown whether cardiac remodeling is also present and if these changes already manifest in prenatal life. Our aim was to assess fetal and infant (6 months of age) cardiovascular function in ART pregnancies. METHODS AND RESULTS: This prospective cohort study included 100 fetuses conceived by ART and 100 control pregnancies. ART fetuses showed signs of cardiovascular remodeling, including a more globular heart with thicker myocardial walls, decreased longitudinal function (tricuspid ring displacement in controls: median, 6.5 mm [interquartile range, 6.1-7.1 mm]; tricuspid ring displacement in ART: 5.5 mm [interquartile range, 5.1-6.1]; P<0.001), impaired relaxation, and dilated atria (atrial area in controls, 1.46 cm(2) [interquartile range, 1.2-1.5 cm(2)]; atrial area in ART, 1.6 cm(2) [interquartile range, 1.3-1.8 cm(2)]; P<0.001). Additionally, ARTinfants showed persistence of most cardiac changes and a significant increase in blood pressure and aortic intima-media thickness (systolic blood pressure in controls, 74 mm Hg [interquartile range, 67-83 mm Hg]; systolic blood pressure in ART, 83 mm Hg [interquartile range, 75-94 mm Hg]; P<0.001; aortic intima-media thickness in controls, 0.52 mm [interquartile range, 0.45-0.56 mm]; aortic intima-media thickness in ART, 0.64 mm [interquartile range, 0.62-0.67]; P<0.001). We could not demonstrate that our findings were directly caused by ART because of their association with various confounding factors, including intrauterine growth restriction or factors related to the cause of infertility. CONCLUSIONS:Children conceived by ART manifest cardiac and vascular remodeling that is present in fetal life and persists in postnatal life, suggesting opportunities for early detection and potential intervention. The underlying mechanisms and the effect of potential confounders such as growth restriction or prematurity remain to be elucidated.
Authors: Wendy Y Zhang; Elif Seda Selamet Tierney; Angela C Chen; Albee Y Ling; Raquel R Fleischmann; Valerie L Baker Journal: J Pediatr Date: 2019-08-20 Impact factor: 4.406
Authors: Tom P Fleming; Adam J Watkins; Miguel A Velazquez; John C Mathers; Andrew M Prentice; Judith Stephenson; Mary Barker; Richard Saffery; Chittaranjan S Yajnik; Judith J Eckert; Mark A Hanson; Terrence Forrester; Peter D Gluckman; Keith M Godfrey Journal: Lancet Date: 2018-04-16 Impact factor: 79.321
Authors: Mahesh Bavineni; Trudy M Wassenaar; Kanishk Agnihotri; David W Ussery; Thomas F Lüscher; Jawahar L Mehta Journal: Eur Heart J Date: 2019-04-07 Impact factor: 29.983
Authors: Christopher D Kassotis; John J Bromfield; Kara C Klemp; Chun-Xia Meng; Andrew Wolfe; R Thomas Zoeller; Victoria D Balise; Chiamaka J Isiguzo; Donald E Tillitt; Susan C Nagel Journal: Endocrinology Date: 2016-08-25 Impact factor: 4.736