Literature DB >> 2398438

Thoratec VAD system as a bridge to heart transplantation.

D J Farrar1, J H Lawson, P Litwak, G Cederwall.   

Abstract

As of October 1988 the Thoratec ventricular assist device system was used in 72 heart transplant candidates at 20 medical centers in five countries. All patients were in imminent risk of dying before donor heart procurement, with a mean cardiac index of 1.6 +/- 0.5 L/min/m2 and a pulmonary capillary wedge pressure of 27 +/- 8 mm Hg, in spite of maximal medical therapy. The ventricular assist device system consists of a prosthetic ventricle (Pierce-Donachy design) with a 65 ml pumping chamber, made of Thoratec's BPS-215M polyurethane, appropriate cannulae for atrial or ventricular inflow and for arterial outflow connections, and a pneumatic drive console. The devices can be used for partial or complete support of the pulmonary and systemic circulations. Fifty-eight (81%) of the 72 patients received biventricular devices and 14 received support only on the left side of the heart. Average flow rate was 5.0 +/- 0.7 L/min on the left side and 4.3 +/- 0.7 on the right. Fifty-four patients (75%) recovered sufficiently to undergo heart transplantation after a median of 4.4 days (mean, 14.3 days; range, 8 hours to 81 days), and 45 of them have been discharged from the hospital (83% early posttransplant survival and 63% overall survival from implant to discharge). Of 14 patients supported for more than 30 days, 11 underwent heart transplantation, and nine were discharged alive. The actuarial 1- and 2-year posttransplant survival rates are 78% and 75%. We conclude that these heterotopic prosthetic devices provide an effective method of maintaining blood flow to vital organs until a donor heart can be procured.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2398438

Source DB:  PubMed          Journal:  J Heart Transplant        ISSN: 0887-2570


  5 in total

Review 1.  Percutaneous left ventricular assist devices during cardiogenic shock and high-risk percutaneous coronary interventions.

Authors:  Stéphane Cook; Stephan Windecker
Journal:  Curr Cardiol Rep       Date:  2009-09       Impact factor: 2.931

Review 2.  Ventricular assist devices: history, patient selection, and timing of therapy.

Authors:  Daniel G Tang; Philip E Oyer; Hari R Mallidi
Journal:  J Cardiovasc Transl Res       Date:  2009-03-19       Impact factor: 4.132

Review 3.  Percutaneous ventricular assist devices for cardiogenic shock.

Authors:  Stéphane Cook; Stephan Windecker
Journal:  Curr Heart Fail Rep       Date:  2008-09

4.  Percutaneous ventricular assist devices: new deus ex machina?

Authors:  Diego Arroyo; Stéphane Cook
Journal:  Minim Invasive Surg       Date:  2011-07-31

5.  Surgical outcomes of bridge-to-bridge therapy with extracorporeal left ventricular assist device for acute myocardial infarction in cardiogenic shock.

Authors:  Chiho Tokunaga; Atsushi Iguchi; Hiroyuki Nakajima; Fumiya Chubachi; Yuto Hori; Akitoshi Takazawa; Jun Hayashi; Toshihisa Asakura; Akihiro Yoshitake
Journal:  BMC Cardiovasc Disord       Date:  2022-02-16       Impact factor: 2.298

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.