Literature DB >> 23982115

Transpedicular vertebral body augmentation reinforced with pedicle screw fixation in fresh traumatic A2 and A3 lumbar fractures: comparison between two devices and two bone cements.

Panagiotis Korovessis1, Konstantinos Vardakastanis, Thomas Repantis, Vasilios Vitsas.   

Abstract

This retrospective study compares efficacy and safety of balloon kyphoplasty (BK) with calcium phosphate (Group A) versus KIVA implant with PMMA (Group B) reinforced with three vertebrae pedicle screw constructs for A2 and A3 single fresh non-osteoporotic lumbar (L1-L4) fractures in 38 consecutive age- and diagnosis-matched patient populations. Extracanal leakage of both low-viscosity PMMA and calcium phosphate (CP) as well as the following roentgenographic parameters: segmental kyphosis (SKA), anterior (AVBHr) and posterior (PVBHr) vertebral body height ratio, spinal canal encroachment (SCE) clearance, and functional outcome measures: VAS and SF-36, were recorded and compared between the two groups. All patients in both groups were followed for a minimum 26 (Group A) and 25 (Group B) months. Extracanal CP and PMMA leakage was observed in four (18 %) and three (15 %) vertebrae/patients of group A and B, respectively. Hybrid fixation improved AVBHr, SKA, SCE, but PVBHr only in group B. VAS and SF-36 improved postoperatively in the patients of both groups. Short-segment construct with the novel KIVA implant restored better than BK-fractured lumbar vertebral body, but this had no impact in functional outcome. Since there was no leakage difference between PMMA and calcium phosphate and no short-term adverse related to PMMA use were observed, we advice the use of PMMA in fresh traumatic lumbar fractures.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23982115     DOI: 10.1007/s00590-013-1296-9

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  31 in total

1.  Percutaneous placement of pedicle screws in overweight and obese patients.

Authors:  Yung Park; Joong Won Ha; Yun Tae Lee; Na Young Sung
Journal:  Spine J       Date:  2011-09-08       Impact factor: 4.166

2.  Transpedicle body augmenter in painful osteoporotic compression fractures.

Authors:  Kung-Chia Li; Anna F-Y Li; Ching-Hsiang Hsieh; Hsiang-Ho Chen
Journal:  Eur Spine J       Date:  2006-09-07       Impact factor: 3.134

3.  Short-segment fixation of lumbar burst fractures using pedicle fixation at the level of the fracture.

Authors:  Andrew Mahar; Choll Kim; Michelle Wedemeyer; Lance Mitsunaga; Tim Odell; Bryce Johnson; Steven Garfin
Journal:  Spine (Phila Pa 1976)       Date:  2007-06-15       Impact factor: 3.468

4.  The treatment of acute thoracolumbar burst fractures with transpedicular intracorporeal hydroxyapatite grafting following indirect reduction and pedicle screw fixation: a prospective study.

Authors:  Tomoaki Toyone; Tadashi Tanaka; Daisuke Kato; Ryutaku Kaneyama; Makoto Otsuka
Journal:  Spine (Phila Pa 1976)       Date:  2006-04-01       Impact factor: 3.468

5.  Is fusion necessary for surgically treated burst fractures of the thoracolumbar and lumbar spine?: a prospective, randomized study.

Authors:  Shih-Tien Wang; Hsiao-Li Ma; Chien-Lin Liu; Wing-Kwong Yu; Ming-Chau Chang; Tain-Hsiung Chen
Journal:  Spine (Phila Pa 1976)       Date:  2006-11-01       Impact factor: 3.468

6.  Minimal invasive short posterior instrumentation plus balloon kyphoplasty with calcium phosphate for burst and severe compression lumbar fractures.

Authors:  Panagiotis Korovessis; Alexander Hadjipavlou; Thomas Repantis
Journal:  Spine (Phila Pa 1976)       Date:  2008-03-15       Impact factor: 3.468

7.  [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty].

Authors:  P Galibert; H Deramond; P Rosat; D Le Gars
Journal:  Neurochirurgie       Date:  1987       Impact factor: 1.553

8.  Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report.

Authors:  R F McLain; E Sparling; D R Benson
Journal:  J Bone Joint Surg Am       Date:  1993-02       Impact factor: 5.284

9.  Posterior short-segment fixation with or without fusion for thoracolumbar burst fractures. a five to seven-year prospective randomized study.

Authors:  Li-Yang Dai; Lei-Sheng Jiang; Sheng-Dan Jiang
Journal:  J Bone Joint Surg Am       Date:  2009-05       Impact factor: 5.284

10.  Biomechanical comparison of kyphoplasty with different bone cements.

Authors:  Seiji Tomita; Sean Molloy; Louis E Jasper; Muneaki Abe; Stephen M Belkoff
Journal:  Spine (Phila Pa 1976)       Date:  2004-06-01       Impact factor: 3.468

View more
  7 in total

1.  Clinical, radiological, and patient-reported outcomes 13 years after pedicle screw fixation with balloon-assisted endplate reduction and cement injection.

Authors:  Erin E A De Gendt; Jonneke S Kuperus; Wouter Foppen; F Cumhur Oner; Jorrit-Jan Verlaan
Journal:  Eur Spine J       Date:  2020-02-08       Impact factor: 3.134

2.  Percutaneous pedicle screw fixation plus kyphoplasty for thoracolumbar fractures A2, A3 and B2.

Authors:  Panagiotis Korovessis; Eva Mpountogianni; Vasilleios Syrimpeis
Journal:  Eur Spine J       Date:  2016-08-23       Impact factor: 3.134

3.  Bony healing of unstable thoracolumbar burst fractures in the elderly using percutaneously applied titanium mesh cages and a transpedicular fixation system with expandable screws.

Authors:  Anica Eschler; Stephan Albrecht Ender; Katharina Schiml; Thomas Mittlmeier; Georg Gradl
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

4.  Cementless Titanium Mesh Fixation of Osteoporotic Burst Fractures of the Lumbar Spine Leads to Bony Healing: Results of an Experimental Sheep Model.

Authors:  Anica Eschler; Paula Roepenack; Jan Roesner; Philipp Karl Ewald Herlyn; Heiner Martin; Martin Reichel; Robert Rotter; Brigitte Vollmar; Thomas Mittlmeier; Georg Gradl
Journal:  Biomed Res Int       Date:  2016-02-25       Impact factor: 3.411

5.  A Hybrid Uniplanar Pedicle Screw System with a New Intermediate Screw for Minimally Invasive Spinal Fixation: A Finite Element Analysis.

Authors:  Jia Li; Li-Cheng Zhang; Jiantao Li; Hao Zhang; Jing-Xin Zhao; Wei Zhang
Journal:  Biomed Res Int       Date:  2020-11-18       Impact factor: 3.411

6.  Transpedicular bone grafting and pedicle screw fixation in injured vertebrae using a paraspinal approach for thoracolumbar fractures: a retrospective study.

Authors:  Qinliang Li; Cai Yun; Shichun Li
Journal:  J Orthop Surg Res       Date:  2016-10-17       Impact factor: 2.359

7.  Percutaneous Injection of Strontium Containing Hydroxyapatite versus Polymethacrylate Plus Short-Segment Pedicle Screw Fixation for Traumatic A2- and A3/AO-Type Fractures in Adults.

Authors:  Panagiotis Korovessis; Eva Mpountogianni; Vasileios Syrimpeis; Andreas Baikousis; Vasileios Tsekouras
Journal:  Adv Orthop       Date:  2018-03-05
  7 in total