Literature DB >> 23975566

Double-lumen tube tracheal intubation using a rigid video-stylet: a randomized controlled comparison with the Macintosh laryngoscope.

M Yang1, J A Kim, H J Ahn, J W Choi, D K Kim, E A Cho.   

Abstract

BACKGROUND: Despite an increasing need, there is limited experience of double-lumen endobronchial tube (DLT) placement using video laryngoscope. We evaluated DLT intubation using an OptiScope, a rigid video-stylet with a malleable tip derived from the Clarus Video System, in comparison with a Macintosh laryngoscope.
METHODS: After airway evaluation and anaesthetic induction, Cormack and Lehane (C and L) grade was initially assessed in all patients using a Macintosh laryngoscope before tracheal intubation. The trachea was then intubated using either a Macintosh laryngoscope (n=200) or an OptiScope® (n=200). Success rate, intubation time, number of attempts at intubation, vocal cord view during intubation, need for external manipulation, and the incidences of oral mucosal or dental injury were compared between the two devices.
RESULTS: Data were analysed for 397 patients. Intubation time with the OptiScope® was faster [median (inter-quartile range): 15 (12-19) s] than with the Macintosh [18(12-28) s] {mean difference [95% confidence interval (CI)}: 5.5 (3.8-13.2) s, P=0.010]. The success rate of the first intubation was higher with the OptiScope® than with the Macintosh [80.4% vs 89.9%, odds ratio (95% CI): 2.2 (1.22-3.87), P=0.036]. Initial view of the vocal cords was also better, although the final success rate was not different between devices. The need for external laryngeal manipulation, oral mucosal, or dental injury was lower with the OptiScope® compared with the Macintosh laryngoscope (all P<0.01).
CONCLUSIONS: The OptiScope® provides faster tracheal intubation and a higher success rate for the first intubation with less trauma and a better vocal cord view than the Macintosh laryngoscope.

Entities:  

Keywords:  equipment, tubes, double-lumen; laryngoscope; thoracic anaesthesia

Mesh:

Year:  2013        PMID: 23975566     DOI: 10.1093/bja/aet281

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  17 in total

1.  Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients.

Authors:  Amro Faez Abdelgawad; Qin-Fang Shi; Mohamed Abo Halawa; Zhi-Lin Wu; Zhou-Yang Wu; Xiang-Dong Chen; Shang-Long Yao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2015-06-14

Review 2.  Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation.

Authors:  Sharon R Lewis; Andrew R Butler; Joshua Parker; Tim M Cook; Andrew F Smith
Journal:  Cochrane Database Syst Rev       Date:  2016-11-15

3.  Video-Assisted Intubating Stylet Technique for Difficult Intubation: A Case Series Report.

Authors:  Pei-Jiuan Tsay; Chih-Pin Yang; Hsiang-Ning Luk; Jason Zhensheng Qu; Alan Shikani
Journal:  Healthcare (Basel)       Date:  2022-04-15

4.  Bonfils assisted double lumen endobronchial tube placement in an anticipated difficult airway.

Authors:  Sudhakar Subramani; Ruban Poopalalingam
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-10

Review 5.  Videolaryngoscopes for placement of double lumen tubes: Is it time to say goodbye to direct view?

Authors:  M R El-Tahan
Journal:  Saudi J Anaesth       Date:  2016 Apr-Jun

6.  The Fast and Easy Way for Double-Lumen Tube Intubation: Individual Angle-Modification.

Authors:  Jeong Jin Min; Jong-Hwan Lee; Se Hee Kang; Eunhee Kim; Sangmin M Lee; Jong Ho Cho; Hong Kwan Kim
Journal:  PLoS One       Date:  2016-08-18       Impact factor: 3.240

7.  McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation: A randomized trial.

Authors:  Li Wan; Mingfeng Liao; Li Li; Wei Qian; Rong Hu; Kun Chen; Chuanhan Zhang; Wenlong Yao
Journal:  Medicine (Baltimore)       Date:  2016-12       Impact factor: 1.889

8.  Case Report: Double lumen tube insertion in a morbidly obese patient through the non-channelled blade of the King Vision (™) videolaryngoscope.

Authors:  Mohamed El-Tahan; D John Doyle; Alaa M Khidr; Ahmed G Hassieb
Journal:  F1000Res       Date:  2014-06-17

9.  Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy.

Authors:  Wei Wei; Ming Tian
Journal:  Pak J Med Sci       Date:  2016 Jan-Feb       Impact factor: 1.088

10.  A comparative evaluation of Video Stylet and flexible fibre-optic bronchoscope in the performance of intubation in adult patients.

Authors:  Syed Hussain Amir; Qazi Ehsan Ali; Sonali Bansal
Journal:  Indian J Anaesth       Date:  2017-04
View more