Literature DB >> 23975383

On the characterization of a non-Newtonian blood analog and its response to pulsatile flow downstream of a simplified stenosis.

Andrew M Walker1, Clifton R Johnston, David E Rival.   

Abstract

Particle image velocimetry (PIV) was used to investigate the influence of a non-Newtonian blood analog of aqueous xanthan gum on flow separation in laminar and transitional environments and in both steady and pulsatile flow. Initial steady pressure drop measurements in laminar and transitional flow for a Newtonian analog showed an extension of laminar behavior to Reynolds number (Re) ~ 2900 for the non-Newtonian case. On a macroscale level, this showed good agreement with porcine blood. Subsequently, PIV was used to measure flow patterns and turbulent statistics downstream of an axisymmetric stenosis in the aqueous xanthan gum solution and for a Newtonian analog at Re ~ 520 and Re ~ 1250. The recirculation length for the non-Newtonian case was reduced at Re ~ 520 resultant from increased viscosity at low shear strain rates. At Re ~ 1250, peak turbulent intensities and turbulent shear stresses were dampened by the non-Newtonian fluid in close proximity to the blockage outlet. Although the non-Newtonian case's recirculation length was increased at peak pulsatile flow, turbulent shear stress was found to be elevated for the Newtonian case downstream from the blockage, suggesting shear layer fragmentation and radial transport. Our findings conclude that the xanthan gum elastic polymer prolongs flow stabilization, which in turn emphasizes the importance of non-Newtonian blood characteristics on the resulting flow patterns in such cardiovascular environments.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23975383     DOI: 10.1007/s10439-013-0893-4

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  3 in total

1.  Variations in pulsatile flow around stenosed microchannel depending on viscosity.

Authors:  Hyeonji Hong; Jae Min Song; Eunseop Yeom
Journal:  PLoS One       Date:  2019-01-24       Impact factor: 3.240

2.  Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

Authors:  M Y Abdollahzadeh Jamalabadi; Amin Ali Akbari Bidokhti; Hamid Khak Rah; Siavash Vaezi; Payam Hooshmand
Journal:  PLoS One       Date:  2016-12-12       Impact factor: 3.240

3.  Recanalization of Embolized Endovascular Intracranial Aneurysms and Changes in the Blood Viscosity: A Pilot Study.

Authors:  Rafał Morga; Marek Moskała; Tadeusz Popiela; Marek Rajzer; Aleksander Wilk; Michał Kłosiński; Tomasz Muszyński; Mariusz Trystuła
Journal:  Med Sci Monit       Date:  2020-03-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.