BpTRUth: do automated blood pressure monitors outperform mercury?

Cedric Edwards1, Swapnil Hiremath2, Ankur Gupta3, Brendan B McCormick3, Marcel Ruzicka4.   

Abstract

Manual measurement of blood pressure (BP) in the office (MOBP) is inferior in accuracy when compared with ambulatory BP measurements (ABPM) since it misses white coat and masked effects on BP. BpTRU, an automated office BP device (AOBP), has been reported to reduce white coat effect. We performed a retrospective review of the diagnostic accuracy of MOBP (taken by a trained nurse in clinical hypertension) and AOBP using the Bland-Altman method in hypertensive patients referred to a Renal Hypertension Clinic. In 329 hypertensive patients, the 95% limits of agreement between systolic AOBP and ABPM were -31 mm Hg to 33 mm Hg and for MOBP and ABPM were -27.8 mm Hg to 37.4 mm Hg. The bias between systolic MOBP and systolic ABPM was 4.9 mm Hg (95% confidence interval, 3.0-6.6 mm Hg) whereas the bias between the systolic AOBP and the systolic ABPM was -3.2 (95% confidence interval, -1.3 to -5.0). AOBP did not improve treatment relevant classification errors compared with MOBP (28% vs. 23%; P = .052). Our data support findings by others showing that AOBP improves, but does not eliminate, white coat effect. The increased detection of white coat effect appears related to systematic downward bias by BpTRU. As a result, detection of masked effect is undermined by BpTRU.
Copyright © 2013 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  White coat effect; automated oscillometric blood pressure; masked effect

Mesh:

Substances:

Year:  2013        PMID: 23969286     DOI: 10.1016/j.jash.2013.07.002

Source DB:  PubMed          Journal:  J Am Soc Hypertens        ISSN: 1878-7436


  8 in total

Review 1.  Clinical Implications of Different Blood Pressure Measurement Techniques.

Authors:  Paul Drawz
Journal:  Curr Hypertens Rep       Date:  2017-07       Impact factor: 5.369

2.  Associations between cystatin C-based eGFR, ambulatory blood pressure parameters, and in-clinic versus ambulatory blood pressure agreement in older community-living adults.

Authors:  Tyler B Woodell; Jan M Hughes-Austin; Tiffany V Tran; Atul Malhotra; Joseph A Abdelmalek; Dena E Rifkin
Journal:  Blood Press Monit       Date:  2016-04       Impact factor: 1.444

Review 3.  BP Measurement in Clinical Practice: Time to SPRINT to Guideline-Recommended Protocols.

Authors:  Paul E Drawz; Joachim H Ix
Journal:  J Am Soc Nephrol       Date:  2017-10-19       Impact factor: 10.121

4.  Eliminating the human factor in office blood pressure measurement.

Authors:  Martin G Myers
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-01-04       Impact factor: 3.738

5.  Eliminating the human factor in office blood pressure measurement.

Authors:  Martin G Myers
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-04-26       Impact factor: 3.738

6.  Reply to Dr Myers' commentary on the use of automated blood pressure machines in office blood pressure measurements.

Authors:  Swapnil Hiremath; Cedric Edwards; Brendan B McCormick; Marcel Ruzicka
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-05-07       Impact factor: 3.738

7.  Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis.

Authors:  Michael Roerecke; Janusz Kaczorowski; Martin G Myers
Journal:  JAMA Intern Med       Date:  2019-03-01       Impact factor: 44.409

8.  Quality improvement project for managing elevated blood pressure in a primary care setting.

Authors:  Stephanie M Thomas; Holly B Cassells
Journal:  Integr Blood Press Control       Date:  2017-10-13
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.