Literature DB >> 23968728

Highly specific and sensitive non-enzymatic determination of uric acid in serum and urine by extended gate field effect transistor sensors.

Weihua Guan1, Xuexin Duan, Mark A Reed.   

Abstract

A potentiometric non-enzymatic sensor using off-chip extended-gate field effect transistor (EGFET) with a ferrocenyl-alkanethiol modified gold electrode is demonstrated for determining the uric acid concentration in human serum and urine. Hexacyanoferrate (II) and (III) ions are used as redox reagent. This potentiometric sensor measures the interface potential on the ferrocene immobilized gold electrode, which is modulated by the redox reaction between uric acid and hexacyanoferrate ions. The device shows a near Nernstian response to uric acid and is highly specific. The interference that comes from glucose, bilirubin, ascorbic acid and hemoglobin is negligible in normal concentration range of these interferents. The sensor also exhibits excellent long term reliability. This extended gate field effect transistor based sensors can be used as a point of care UA testing tool, due to the small size, low cost, and low sample volume consumption.
© 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Extended gate FET; Ferrocenyl-alkanethiol; Non-enzymatic; Potentiometric sensor; Uric acid sensor

Mesh:

Substances:

Year:  2013        PMID: 23968728     DOI: 10.1016/j.bios.2013.07.061

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Electronic Cortisol Detection Using an Antibody-Embedded Polymer Coupled to a Field-Effect Transistor.

Authors:  Hyun-June Jang; Taein Lee; Jian Song; Luisa Russell; Hui Li; Jennifer Dailey; Peter C Searson; Howard E Katz
Journal:  ACS Appl Mater Interfaces       Date:  2018-05-03       Impact factor: 9.229

2.  Modeling of Quasi-Static Floating-Gate Transistor Biosensors.

Authors:  Mathew S Thomas; Demetra Z Adrahtas; C Daniel Frisbie; Kevin D Dorfman
Journal:  ACS Sens       Date:  2021-04-22       Impact factor: 7.711

Review 3.  A Fluorescent Biosensors for Detection Vital Body Fluids' Agents.

Authors:  Witold Nawrot; Kamila Drzozga; Sylwia Baluta; Joanna Cabaj; Karol Malecha
Journal:  Sensors (Basel)       Date:  2018-07-24       Impact factor: 3.576

4.  A Reliable BioFET Immunosensor for Detection of p53 Tumour Suppressor in Physiological-Like Environment.

Authors:  Chiara Baldacchini; Antonino Francesco Montanarella; Luca Francioso; Maria Assunta Signore; Salvatore Cannistraro; Anna Rita Bizzarri
Journal:  Sensors (Basel)       Date:  2020-11-08       Impact factor: 3.576

5.  Noise immune dielectric modulated dual trench transparent gate engineered MOSFET as a label free biosensor: proposal and investigation.

Authors:  Dipanjan Sen; Arpan De; Bijoy Goswami; Sharmistha Shee; Subir Kumar Sarkar
Journal:  J Comput Electron       Date:  2021-09-30       Impact factor: 1.807

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.