Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

Jan Vandecasteele1, Yves De Deene.   

Abstract

A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed to a 6 MV photon beam and the depth dose was compared against a diamond detector measurement that served as golden standard. Both gel dosimeters were found accurate within 4% accuracy. In the 3D dose matrix of the radiochromic gel, hotspot dose deviations up to 8% were observed which are attributed to the fabrication procedure. The polymer gel readout was shown to be sensitive to B0 field and B1 field non-uniformities as well as temperature variations during scanning. The performance of the two gel dosimeters was also evaluated for a brain tumour IMRT treatment. Both gel measured dose distributions were compared against treatment planning system predicted dose maps which were validated independently with ion chamber measurements and portal dosimetry. In the radiochromic gel measurement, two sources of deviations could be identified. Firstly, the dose in a cluster of voxels near the edge of the phantom deviated from the planned dose. Secondly, the presence of dose hotspots in the order of 10% related to inhomogeneities in the gel limit the clinical acceptance of this dosimetry technique. Based on the results of the micelle gel dosimeter prototype presented here, chemical optimization will be subject of future work. Polymer gel dosimetry is capable of measuring the absolute dose in the whole 3D volume within 5% accuracy. A temperature stabilization technique is incorporated to increase the accuracy during short measurements, however keeping the temperature stable during long measurement times in both calibration phantoms and the volumetric phantom is more challenging. The sensitivity of MRI readout to minimal temperature fluctuations is demonstrated which proves the need for adequate compensation strategies.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23965800     DOI: 10.1088/0031-9155/58/18/6241

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator.

Authors:  Yuanyuan Ge; Ricky T O'Brien; Chun-Chien Shieh; Jeremy T Booth; Paul J Keall
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

2.  Validation of Dolphin dosimetry in three dimensional patient-specific quality assurance programme.

Authors:  Niyas Puzhakkal; Abdullah Kallikuzhiyil Kochunny; Dinesh Makuny; Arun Krishnan M P; Ranjith C Poyil; Vysakh Raveendran
Journal:  Rep Pract Oncol Radiother       Date:  2019-08-12

3.  Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small-field animal irradiation studies.

Authors:  Noora Ba Sunbul; Ibrahim Oraiqat; Benjamin Rosen; Cameron Miller; Christopher Meert; Martha M Matuszak; Shaun Clarke; Sara Pozzi; Jean M Moran; Issam El Naqa
Journal:  Med Phys       Date:  2021-02-06       Impact factor: 4.071

4.  Fiducial detection and registration for 3D IMRT QA with organ-specific dose information.

Authors:  Yi-Fang Wang; Olga Dona; Yuanguang Xu; John Adamovics; Cheng-Shie Wuu
Journal:  J Appl Clin Med Phys       Date:  2021-03-31       Impact factor: 2.102

Review 5.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28

6.  Comparison of the Convolution algorithm with TMR10 for Leksell Gamma knife and dosimetric verification with radiochromic gel dosimeter.

Authors:  Petra Osmancikova; Josef Novotny; Jaroslav Solc; Jan Pipek
Journal:  J Appl Clin Med Phys       Date:  2017-12-10       Impact factor: 2.102

7.  Validation of a secondary dose check tool against Monte Carlo and analytical clinical dose calculation algorithms in VMAT.

Authors:  Stefano Piffer; Marta Casati; Livia Marrazzo; Chiara Arilli; Silvia Calusi; Isacco Desideri; Franco Fusi; Stefania Pallotta; Cinzia Talamonti
Journal:  J Appl Clin Med Phys       Date:  2021-03-18       Impact factor: 2.102

Review 8.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.