Literature DB >> 23965349

Outcome of patients after emergency conversion from transcatheter aortic valve implantation to surgery.

Ralph Hein1, Mohamed Abdel-Wahab, Horst Sievert, Karl-Heinz Kuck, Matthias Voehringer, Rainer Hambrecht, Stefan Sack, Karl E Hauptmann, Jochen Senges, Ralf Zahn, Harald Mudra.   

Abstract

AIMS: To evaluate: 1) the causes of emergency conversion from transcatheter aortic valve implantation (TAVI) to surgery, 2) procedural settings, and 3) short-term outcome of converted patients. METHODS AND
RESULTS: The prospective German TAVI registry was used to identify patients who underwent bail-out surgery during TAVI. Additionally, standardised questionnaires were developed and used to assess more detailed periprocedural and postprocedural data. Emergency conversion from TAVI to open cardiac surgery was required in 24 of 1,975 patients (1.2%). Primary conversion causes were aorto-valvular complications (i.e., aortic annulus rupture, aortic perforation, or thoracic aortic dissection). This was followed by prosthesis embolisation, myocardial perforation, severe aortic regurgitation, and coronary obstructions. The mean time interval between abortions of TAVI to surgery was 19 minutes (SD ± 17 min, range 5-80 min). Four of 24 patients (16.7%) died during the initial surgery, seven of 24 (29.2%) within the first 72 hours and the 30-day mortality was 45.8%. The highest mortality was observed in patients with aortic perforation or dissection (4/5, 80%). Mortality rates for other entities were: prosthesis embolisation 40% (2/5), myocardial perforation 50% (2/4), annulus rupture 67% (2/3), severe aortic regurgitation 33% (1/3), and coronary impairment 0% (0/3).
CONCLUSIONS: Emergency conversion from TAVI to surgery is a rare event carrying a mortality of around 45% after 30 days. Outcome of converted patients with prior injury of aortic, aorto-valvular, or myocardial tissue during TAVI was poor, whereas patients with severe aortic regurgitation and those with coronary complications had a more favourable outcome after 30 days. Collected procedural and outcome data demand on-site cardiac surgery as a prerequisite for TAVI and constant process optimisation efforts regarding such emergency scenarios.

Entities:  

Mesh:

Year:  2013        PMID: 23965349     DOI: 10.4244/EIJV9I4A73

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  11 in total

1.  An autopsy case of aortic root rupture with thin porcelain aorta during balloon-expandable transcatheter aortic valve implantation.

Authors:  Hiroto Suzuyama; Tomohiro Sakamoto; Yutaka Konami; Eiji Taguchi; Yoko Horibata; Kazuhiro Nishigami; Koichi Nakao; Takihiro Kamio; Ichiro Ideta; Hideyuki Uesugi; Koutaro Murakami; Yoshikazu Haratake
Journal:  J Cardiol Cases       Date:  2017-09-05

2.  The Current Situation and the Future of Emergent Cardiac Surgery in TAVI.

Authors:  Holger Eggebrecht; Axel Schmermund
Journal:  Interv Cardiol       Date:  2015-03

Review 3.  Annular Rupture During Transcatheter Aortic Valve Implantation: Predictors, Management and Outcomes.

Authors:  J J Coughlan; Thomas Kiernan; Darren Mylotte; Samer Arnous
Journal:  Interv Cardiol       Date:  2018-09

4.  Case report on successful 'bail out' aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure.

Authors:  Piotr Kołsut; Andrzej Juraszek; Piotr Brzozowski; Maciej Dąbrowski; Adam Witkowski; Jacek Różański; Mariusz Kuśmierczyk
Journal:  J Cardiothorac Surg       Date:  2015-03-04       Impact factor: 1.637

5.  Short- and Long-Term Outcome after Emergent Cardiac Surgery during Transcatheter Aortic Valve Implantation.

Authors:  Fei Li; Xu Wang; Yuetang Wang; Xuan Li; Shihua Zhao; Yongjian Wu; Wei Wang
Journal:  Ann Thorac Cardiovasc Surg       Date:  2021-01-15       Impact factor: 1.520

6.  Immediate aortic dissection after transcatheter aortic valve replacement: A case report and review of the literature.

Authors:  Pongprueth Rujirachun; Apichaya Junyavoraluk; Decho Jakrapanichakul; Nattawut Wongpraparut; Narathip Chunhamaneewat; Adisak Maneesai; Pranya Sakiyalak
Journal:  Clin Case Rep       Date:  2021-07-06

7.  The effect of X-ray beam distortion on the Edwards Sapien XT(™) trans-catheter aortic valve replacement prosthesis.

Authors:  James A Crowhurst; Karl K Poon; Dale Murdoch; Alexander Incani; Owen C Raffel; Annelise Liddicoat; Darren Walters
Journal:  J Med Radiat Sci       Date:  2015-08-30

8.  Conservative management of aortic root rupture complicated with cardiac tamponade following transcatheter aortic valve implantation.

Authors:  Luca Vannini; Rut Andrea; Manel Sabaté
Journal:  World J Cardiol       Date:  2017-04-26

9.  Commentary: An ounce of prevention.

Authors:  Lawrence M Wei; Vinay Badhwar
Journal:  JTCVS Tech       Date:  2021-01-20

10.  Surgery after transcatheter aortic valve interventions.

Authors:  Christopher R Burke; Shakirat O Oyetunji; Gabriel S Aldea
Journal:  JTCVS Tech       Date:  2021-01-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.