Literature DB >> 23964716

Evaluation of Peri-Implant Bone Response in Implants Retrieved for Fracture After More Than 20 Years of Loading: A Case Series.

Carlo Mangano1, Adriano Piattelli2, Carmen Mortellaro3, Francesco Mangano1, Vittoria Perrotti2, Giovanna Iezzi2.   

Abstract

Analysis of human retrieved dental implants is a useful tool in the evaluation of implant success and failure. More human histological data are needed from samples of long-term implant service. The aim of the present case series was a histological and histomorphometrical evaluation of the peri-implant bone responses in implants retrieved for fracture after more than 20 years loading. The archives of the Implant Retrieval Center of the Department of Medical, Oral and Biotechnological Sciences of the University of Chieti-Pescara, Italy were searched. A total of 5 implants, retrieved after a loading period of more than 20 years, were found: 2 had been retrieved after 20 years, 1 after 22 years, 1 after 25 years, and 1 after 27 years. All these implants were histologically processed. Compact, mature bone in close contact with the implant surface was observed in all specimens, with no gaps or connective tissue at the interface. Bone in different maturation stages was found around some implants. Primarily newly formed bone was observed in proximity of the implant surface, while mature compact bone with many remodeling areas and cement lines were detected in areas distant from the implant. Many primary and secondary osteons were present. Bone to implant contact percentage varied from 37.2% to 76%. In conclusion, histology and histomorphometry showed that even after many years of function, all implants presented more than adequate bone to implant contact and they appeared to be very well integrated in the peri-implant bone.

Entities:  

Keywords:  bone remodeling; human histology, implant surfaces; retrieved dental implants

Mesh:

Substances:

Year:  2013        PMID: 23964716     DOI: 10.1563/AAID-JOI-D-13-00037

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

Review 1.  Dental implant fractures - aetiology, treatment and case report.

Authors:  Coelho Goiato Marcelo; Marcela Filié Haddad; Humberto Gennari Filho; Luiz Marcelo Ribeiro Villa; Daniela Micheline Dos Santos; Alves Pesqueira Aldiéris
Journal:  J Clin Diagn Res       Date:  2014-03-15

2.  Histological Evidence of the Osseointegration of Fractured Direct Metal Laser Sintering Implants Retrieved after 5 Years of Function.

Authors:  Francesco Mangano; Carlo Mangano; Adriano Piattelli; Giovanna Iezzi
Journal:  Biomed Res Int       Date:  2017-08-27       Impact factor: 3.411

3.  Fixed Full Arches Supported by Tapered Implants with Knife-Edge Thread Design and Nanostructured, Calcium-Incorporated Surface: A Short-Term Prospective Clinical Study.

Authors:  Soheil Bechara; Algirdas Lukosiunas; Giorgio Andrea Dolcini; Ricardas Kubilius
Journal:  Biomed Res Int       Date:  2017-01-29       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.