Literature DB >> 23962782

Tele-accelerometry as a novel technique for assessing functional status in patients with heart failure: feasibility, reliability and patient safety.

Melissa Jehn1, Sandra Prescher, Kerstin Koehler, Stephan von Haehling, Sebastian Winkler, Oliver Deckwart, Marcus Honold, Udo Sechtem, Gert Baumann, Martin Halle, Stefan D Anker, Friedrich Koehler.   

Abstract

BACKGROUND: The six-minute walk test (6MWT) is an established measure of functional exercise capacity associated with clinical prognosis in Chronic Heart Failure (CHF). The aim of this study is to evaluate the employment of tele-accelerometry for the remote assessment of 6MWT in CHF.
METHODS: 155 patients were subjected to tele-accelerometry in form of monthly 6MWTs in their home surroundings. Accelerometer output included steps/6 min and walking speed. Data was directly transferred via mobile network to the Telemedicine Centre subsequent to test completion. 6MWT distance was measured by hand wheel and steps were counted with a digital hand-counter at baseline (Test 1) and at 12 months follow-up (Test 2).
RESULTS: Accelerometer accuracy was within the 99th percentile. There was a significant correlation between step count, walking speed and measured 6MWT distance (Test 1: steps: r=0.80, P<0.001; Test 2: steps: r=0.90, P<0.001 and Walking Speed Test 1: r=0.80, P<0.001; Walking Speed Test 2: r=0.86, P<0.001). The reproducibility of tele-accelerometry was within 95% margin for all performance parameters, which showed stronger associations to quality of life questionnaire (Short Form - 36) Physical Component Score (PCS) than New York Heart Association (NYHA) functional class.
CONCLUSION: Tele-accelerometry is feasible in patients with CHF and output parameters are indicative of exercise capacity. The benefit of this approach lies in its simplicity under every day circumstances by enabling routine performance testing to assess patients' functional status.
© 2013.

Entities:  

Keywords:  6-Minute walk test; Activity monitoring; Exercise testing; Systolic heart failure; TIM-HF trial; Telemedicine

Mesh:

Year:  2013        PMID: 23962782     DOI: 10.1016/j.ijcard.2013.07.171

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  16 in total

Review 1.  Trials of implantable monitoring devices in heart failure: which design is optimal?

Authors:  William T Abraham; Wendy G Stough; Ileana L Piña; Cecilia Linde; Jeffrey S Borer; Gaetano M De Ferrari; Roxana Mehran; Kenneth M Stein; Alphons Vincent; Jay S Yadav; Stefan D Anker; Faiez Zannad
Journal:  Nat Rev Cardiol       Date:  2014-08-12       Impact factor: 32.419

2.  Teleassessment of Gait and Gait Aids: Validity and Interrater Reliability.

Authors:  Kavita Venkataraman; Kristopher Amis; Lawrence R Landerman; Kevin Caves; Gerald C Koh; Helen Hoenig
Journal:  Phys Ther       Date:  2020-04-17

Review 3.  [Non-device-based telemonitoring : Toy or tool?]

Authors:  Martin Stockburger
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-08-22

4.  Intra- and Interrater Reliability of Remote Assessment of Transfers by Wheelchair Users Using the Transfer Assessment Instrument (Version 4.0).

Authors:  Lynn A Worobey; Rachel Hibbs; Stephanie K Rigot; Michael L Boninger; Randall Huzinec; Jong H Sung; Laura A Rice
Journal:  Arch Phys Med Rehabil       Date:  2021-03-10       Impact factor: 4.060

5.  Monitoring and detection platform to prevent anomalous situations in home care.

Authors:  Gabriel Villarrubia; Javier Bajo; Juan F De Paz; Juan M Corchado
Journal:  Sensors (Basel)       Date:  2014-06-05       Impact factor: 3.576

6.  Novel algorithm for a smartphone-based 6-minute walk test application: algorithm, application development, and evaluation.

Authors:  Nicole A Capela; Edward D Lemaire; Natalie Baddour
Journal:  J Neuroeng Rehabil       Date:  2015-02-20       Impact factor: 4.262

7.  Variability in Physical Activity Assessed with Accelerometer Is an Independent Predictor of Mortality in CHF Patients.

Authors:  Michael Melin; Inger Hagerman; Adrian Gonon; Thomas Gustafsson; Eric Rullman
Journal:  PLoS One       Date:  2016-04-07       Impact factor: 3.240

8.  Lifestyle intervention in BRCA1/2 mutation carriers: study protocol for a prospective, randomized, controlled clinical feasibility trial (LIBRE-1 study).

Authors:  Marion Kiechle; Christoph Engel; Anika Berling; Katrin Hebestreit; Stephan Bischoff; Ricarda Dukatz; Wolf-Dieter Gerber; Michael Siniatchkin; Katharina Pfeifer; Sabine Grill; Maryam Yahiaoui-Doktor; Ellen Kirsch; Uwe Niederberger; Nicole Marter; Ute Enders; Markus Löffler; Alfons Meindl; Kerstin Rhiem; Rita Schmutzler; Nicole Erickson; Martin Halle
Journal:  Pilot Feasibility Stud       Date:  2016-12-19

9.  Accuracy of a step counter during treadmill and daily life walking by healthy adults and patients with cardiac disease.

Authors:  Charlotte Brun Thorup; Jan Jesper Andreasen; Erik Elgaard Sørensen; Mette Grønkjær; Birthe Irene Dinesen; John Hansen
Journal:  BMJ Open       Date:  2017-03-31       Impact factor: 2.692

10.  A Modified Method for Examining the Walking Pattern and Pace of COPD Patients in a 6-min Walk Test Before and After the Inhalation of Procaterol.

Authors:  Naoto Burioka; Sachiko Nakamoto; Takashi Amisaki; Takuya Horie; Eiji Shimizu
Journal:  Intern Med       Date:  2017-08-01       Impact factor: 1.271

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.