Literature DB >> 23959416

A difficult case of retrieval of an aortic valve and balloon during a transcatheter aortic valve implantation.

Bibombe Patrice Mwipatayi1, Roshan Nair, Jean-Louis Papineau, Vikram Vijayan.   

Abstract

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) represents an emerging therapy for valve replacement in patients not suitable for traditional open repair. As awareness of the procedure grows, case numbers are increasing worldwide. Though this procedure represents a less invasive approach to aortic valve replacement, it is not without complications. PRESENTATION OF CASE: This case presentation describes a serious, previously unreported, complication incurred in an 83-year-old male in whom TAVI was attempted. During deployment of the valve at the aortic annulus, both the valve and accompanying balloon embolised into the thoracic aorta and this was further complicated by migration of the balloon into the abdominal aorta and an aortic dissection. The false lumen of the dissection at the level of the infrarenal aorta was tacked to the aortic adventitial wall using interrupted sutures through a laparotomy. A completion angiogram demonstrated that a flow limited dissection did extend up to both common iliac arteries. This was managed with balloon-expandable covered stents deployed in both common iliac arteries with satisfactory outcome. DISCUSSION: This case occurred as a combination of multiple factors that include lack of burst pacing and poor timing of the balloon inflation. The aortic balloon and the valve had to be removed urgently to avoid ventricular embolization of these structures that can result in a fatal situation.
CONCLUSION: This case presentation describes the management of these complications using a combined open and endovascular approach in a well-equipped hybrid operating theatre, resulting in the patient survival.
Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Aortic stenosis; Aortic valve; Embolization

Year:  2013        PMID: 23959416      PMCID: PMC3785852          DOI: 10.1016/j.ijscr.2013.06.018

Source DB:  PubMed          Journal:  Int J Surg Case Rep        ISSN: 2210-2612


  6 in total

1.  Transcatheter aortic valve replacement malposition and embolization: innovation brings solutions also new challenges.

Authors:  E Murat Tuzcu
Journal:  Catheter Cardiovasc Interv       Date:  2008-10-01       Impact factor: 2.692

Review 2.  Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications.

Authors:  Jean-Bernard Masson; Jan Kovac; Gerhard Schuler; Jian Ye; Anson Cheung; Samir Kapadia; Murat E Tuzcu; Susheel Kodali; Martin B Leon; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2009-09       Impact factor: 11.195

3.  Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

Authors:  Alain Cribier; Helene Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Genevieve Derumeaux; Frederic Anselme; François Laborde; Martin B Leon
Journal:  Circulation       Date:  2002-12-10       Impact factor: 29.690

4.  Transcatheter aortic valve implantation: first results from a multi-centre real-world registry.

Authors:  Ralf Zahn; Ulrich Gerckens; Eberhard Grube; Axel Linke; Horst Sievert; Holger Eggebrecht; Rainer Hambrecht; Stefan Sack; Karl Eugen Hauptmann; Gert Richardt; Hans-Reiner Figulla; Jochen Senges
Journal:  Eur Heart J       Date:  2010-09-23       Impact factor: 29.983

5.  Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team.

Authors:  Sabine Bleiziffer; Hendrik Ruge; Domenico Mazzitelli; Christian Schreiber; Andrea Hutter; Jean-Claude Laborde; Robert Bauernschmitt; Ruediger Lange
Journal:  Eur J Cardiothorac Surg       Date:  2009-02-23       Impact factor: 4.191

6.  Prevention and management of transcatheter balloon-expandable aortic valve malposition.

Authors:  Abdullah M Al Ali; Lukas Altwegg; Eric M Horlick; Christopher Feindel; Christopher R Thompson; Anson Cheung; Ronald G Carere; Karin Humphries; Jian Ye; Jean-Bernard Masson; John G Webb
Journal:  Catheter Cardiovasc Interv       Date:  2008-10-01       Impact factor: 2.692

  6 in total
  2 in total

1.  Effect of Balloon-Expandable Transcatheter Aortic Valve Replacement Positioning: A Patient-Specific Numerical Model.

Authors:  Matteo Bianchi; Gil Marom; Ram P Ghosh; Harold A Fernandez; James R Taylor; Marvin J Slepian; Danny Bluestein
Journal:  Artif Organs       Date:  2016-12       Impact factor: 3.094

2.  Immediate aortic dissection after transcatheter aortic valve replacement: A case report and review of the literature.

Authors:  Pongprueth Rujirachun; Apichaya Junyavoraluk; Decho Jakrapanichakul; Nattawut Wongpraparut; Narathip Chunhamaneewat; Adisak Maneesai; Pranya Sakiyalak
Journal:  Clin Case Rep       Date:  2021-07-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.