Changes in higher-order aberrations after iris-fixated phakic intraocular lens implantation.

Hidemasa Torii, Kazuno Negishi, Kazuhiro Watanabe, Megumi Saiki, Naoko Kato, Kazuo Tsubota.   

Abstract

PURPOSE: To evaluate surgically induced changes in corneal, internal, and ocular higher-order aberrations (HOAs) after phakic intraocular lens (PIOL) implantation and compare them between two PIOLs with different pupillary diameters.
METHODS: Twenty-three eyes with an Artisan PIOL (Ophtec BV, Groningen, The Netherlands) (Artisan group) and 30 eyes with an Artiflex PIOL (Ophtec BV) (Artiflex group) were retrospectively evaluated. The corneal, internal, and ocular HOAs and refractive data were recorded preoperatively and 6 months postoperatively. The root mean squares (RMSs) of the total HOAs from the third- to sixth-order Zernike coefficients were calculated. The RMSs of the third- and fourth-order coefficients represented coma-like aberrations (S3) and spherical-like aberrations (S4), respectively. The main outcome measures were the differences in the parameters among the groups with different pupillary diameters.
RESULTS: The mean postoperative spherical equivalents decreased from -11.84 ± 4.90 to -0.16 ± 0.40 diopters and -9.78 ± 3.20 to -0.09 ± 0.26 diopters in the Artisan and Artiflex groups, respectively. With the 4- and 5-mm pupillary diameters, the postoperative internal and ocular spherical aberrations (Z4(0)) were significantly lower in the Artiflex group than in the Artisan group (4 mm, P = .002, .024; 5 mm, P = .004, .022, respectively). With the 6-mm pupillary diameter, there were no significant postoperative differences in any parameter measured between groups; both groups had positive spherical aberration values.
CONCLUSIONS: The postoperative ocular spherical aberrations were positive after Artisan and Artiflex implantation. The postoperative ocular spherical aberration was greater in the Artisan group, possibly due to differences in the SAs of both PIOLs. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Year:  2013        PMID: 23957754     DOI: 10.3928/1081597X-20130816-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

1.  Ocular higher-order aberrations changes after implantable collamer lens implantation for high myopic astigmatism.

Authors:  Seyed Javad Hashemian; Hosein Farrokhi; Alireza Foroutan; Mohammad Ebrahim Jafari; Seyed Mahyar Hashemian; Sayyed Amirpooya Alemzadeh; Mahsa Sadat Hashemian
Journal:  J Curr Ophthalmol       Date:  2017-11-10

2.  Artisan versus Artiflex phakic intraocular lens implantation in the treatment of moderate to high myopia: meta-analysis.

Authors:  Chenting Hou; Hui Li; Jiangfeng Li; Jinjian Li; Hui Peng; Qing Wang
Journal:  BMC Ophthalmol       Date:  2021-04-10       Impact factor: 2.209

3.  Violet Light Transmission is Related to Myopia Progression in Adult High Myopia.

Authors:  Hidemasa Torii; Kazuhiko Ohnuma; Toshihide Kurihara; Kazuo Tsubota; Kazuno Negishi
Journal:  Sci Rep       Date:  2017-11-06       Impact factor: 4.379

4.  Comparison of rigid versus foldable iris-fixed phakic intraocular lens implantation for high myopia: A systematic review and meta-analysis.

Authors:  Qiong Wu; Yan Li; Li Tang; Li-An Wu; Cong-Yi Wang
Journal:  Medicine (Baltimore)       Date:  2020-02       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.