Literature DB >> 23957708

Fibrin sealant patch for repair of acute type a aortic dissection.

Milan Lisy1, Mahmut Kahlil, Ulrich A Stock, Stephen M Wildhirt.   

Abstract

INTRODUCTION: The use of glues to repair disrupted tissue during acute type-A aortic dissection (TAD) surgery may be discontinuous, and cause embolization and cell necrosis. We report a method of fibrin sealant patch (FSP) to reinforce dissected aortic tissue with a collagen double layer coated with fibrinogen/thrombin on either side (TachoSil®; Takeda, Konstanz, Germany).
METHODS: In 12 patients (seven male, 66.9 ± 11.7 years) with acute TAD we performed FSP of the intima-media disruption at the proximal and distal anastomosis of the aorta. We analyzed the perioperative course and echocardiographical, radiological, and clinical outcomes up to one year. Additionally, we investigated the adhesive potential of the FSP in vitro.
RESULTS: In vitro, the adhesive strength of the FSP was 60 N/cm(2). In-hospital mortality was 8.3% (n = 1), recovery was satisfactory with no major neurologic events, mean ICU stay was 13.6 ± 6.0 days, mean hospital stay was 20.7 ± 4.4 days. A total of 7.0 ± 2.6 RBC, 3.4 ± 1.5 platelets, and 8.0 ± 4.3 FFP were transfused. One-year survival was 83.3%. In 6/6 DeBakey II dissections the intimal tear was completely resected, in 2/6 DeBakey I dissections the false lumen in the descending aorta completely collapsed. No redissections and no relevant aortic valve insufficiencies were seen during follow-up.
CONCLUSION: This analysis shows that FSP using a collagen matrix double layer coated with fibrinogen/thrombin is feasible, safe, and effective in repairing the dissected aortic tissue. It results in continuous reinforcement of aortic tissue and completely avoids the need for conventional glues.
© 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23957708     DOI: 10.1111/jocs.12208

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  3 in total

1.  Analysis of the hemostatic potential of modern topical sealants on arterial and venous anastomoses: an experimental porcine study.

Authors:  Hamidreza Fonouni; Arash Kashfi; Ali Majlesara; Oliver Stahlheber; Lukas Konstantinidis; Thomas W Kraus; Arianeb Mehrabi; Hani Oweira
Journal:  J Mater Sci Mater Med       Date:  2017-07-28       Impact factor: 3.896

2.  Neomedia Repair of the Valsalva Sinus in the Treatment of Acute Type-A Aortic Dissection: Long-term Effectiveness and a Case of Pathology.

Authors:  Nobuhisa Ohno; Toshi Maeda; Otohime Kato; Hirofumi Sato; Go Ueno; Kosuke Yoshizawa
Journal:  Ann Vasc Dis       Date:  2020-09-25

3.  Does the additional usage of a local hemostatic patch reduce bleeding after aortic reimplantation?

Authors:  Stanisław Ostrowski; Ryszard Jaszewski; Tomasz Skowroński; Sławomir Jander; Radosław Zwoliński
Journal:  Arch Med Sci       Date:  2018-02-02       Impact factor: 3.318

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.