Literature DB >> 23957683

Clinical impact of using the deterministic patient dose calculation algorithm Acuros XB for lung stereotactic body radiation therapy.

Hong-Wei Liu1, Zoann Nugent, Ravinder Clayton, Peter Dunscombe, Harold Lau, Rao Khan.   

Abstract

PURPOSE: To evaluate the clinical impact of using the deterministic dose calculation algorithm, Acuros XB, for early stage lung cancer patients undergoing stereotactic body radiotherapy (SBRT).
MATERIAL AND METHODS: Seventy-seven stage I non-small cell lung cancer patients who underwent lung SBRT from 2008 to 2012 at our center were included in this study. All treatment plans originally calculated by the anisotropic analytical algorithm (AAA) were recalculated using the AAA and Acuros XB algorithms with identical monitor units and beam arrangements. The dose, dose distribution, conformality number (CN) and heterogeneity index (HI) of the target were determined for each plan. A paired matched t-test was used to evaluate the difference between the mean dose, the dose distribution, and the CN and HI for the target. The importance of tumor (volume, location), patient (pulmonary functional, body mass index) and treatment (number of SBRT beams) on the dose distributions obtained from the two algorithms was statistically determined using linear regression analyses.
RESULTS: The mean target dose was same for both algorithms. Compared to AAA, a small and significant difference in dose distribution in the target was found for the Acuros XB algorithm, resulting in lower conformity (-2.1%, p < 0.0001) and higher heterogeneity (p < 0.0001) of dose. Single logistic regression identified pulmonary function, number of beams and target location as being correlated with the difference of CN between the two calculations. Multivariate analysis indicated that the patient's pulmonary function (p = 0.0296) was the only predictor for the difference in conformality between the two dose calculation algorithms.
CONCLUSIONS: In lung SBRT, the patient's pulmonary function is responsible for the difference in target dose distribution between the Acuros XB and AAA algorithms. The Acuros XB algorithm could be used to advantage in patients with compromised pulmonary function based on its accurate modeling of lung tissue in comparison to AAA.

Entities:  

Mesh:

Year:  2013        PMID: 23957683     DOI: 10.3109/0284186X.2013.822552

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  14 in total

1.  On the use of AAA and AcurosXB algorithms for three different stereotactic ablative body radiotherapy (SABR) techniques: Volumetric modulated arc therapy (VMAT), intensity modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3D-CRT).

Authors:  Abdulrahman Tajaldeen; Prabhakar Ramachandran; Salem Alghamdi; Moshi Geso
Journal:  Rep Pract Oncol Radiother       Date:  2019-03-23

2.  Comparison of Acuros (AXB) and Anisotropic Analytical Algorithm (AAA) for dose calculation in treatment of oesophageal cancer: effects on modelling tumour control probability.

Authors:  Sriram Padmanaban; Samantha Warren; Anthony Walsh; Mike Partridge; Maria A Hawkins
Journal:  Radiat Oncol       Date:  2014-12-23       Impact factor: 3.481

3.  Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size.

Authors:  Baotian Huang; Lili Wu; Peixian Lin; Chuangzhen Chen
Journal:  Radiat Oncol       Date:  2015-02-26       Impact factor: 3.481

4.  Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy.

Authors:  Markus Oechsner; Leonhard Odersky; Johannes Berndt; Stephanie Elisabeth Combs; Jan Jakob Wilkens; Marciana Nona Duma
Journal:  Radiat Oncol       Date:  2015-12-01       Impact factor: 3.481

5.  Clinical implications of Eclipse analytical anisotropic algorithm and Acuros XB algorithm for the treatment of lung cancer.

Authors:  Gangarapu Sri Krishna; Vuppu Srinivas; Palreddy Yadagiri Reddy
Journal:  J Med Phys       Date:  2016 Oct-Dec

6.  Verification of Acuros XB dose algorithm using 3D printed low-density phantoms for clinical photon beams.

Authors:  Rodolfo Zavan; Philip McGeachy; Joseph Madamesila; Jose-Eduardo Villarreal-Barajas; Rao Khan
Journal:  J Appl Clin Med Phys       Date:  2018-03-25       Impact factor: 2.102

7.  A comparative analysis of Acuros XB and the analytical anisotropic algorithm for volumetric modulation arc therapy.

Authors:  Raju P Srivastava; K Basta; Werner De Gersem; Carlos De Wagter
Journal:  Rep Pract Oncol Radiother       Date:  2021-06-09

8.  A dosimetric comparison of three-dimensional conformal radiotherapy, volumetric-modulated arc therapy, and dynamic conformal arc therapy in the treatment of non-small cell lung cancer using stereotactic body radiotherapy.

Authors:  Bradley M Rauschenbach; Luke Mackowiak; Harish K Malhotra
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

9.  The photon dose calculation algorithm used in breast radiotherapy has significant impact on the parameters of radiobiological models.

Authors:  Saskia Petillion; Ans Swinnen; Gilles Defraene; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

10.  Clinical implementation of AXB from AAA for breast: Plan quality and subvolume analysis.

Authors:  Alexandra Guebert; Leigh Conroy; Sarah Weppler; Majed Alghamdi; Jessica Conway; Lindsay Harper; Tien Phan; Ivo A Olivotto; Wendy L Smith; Sarah Quirk
Journal:  J Appl Clin Med Phys       Date:  2018-04-25       Impact factor: 2.102