Literature DB >> 2395743

Successful treatment of a nondeflatable balloon atrial septostomy catheter.

N J Wilson1, J A Culham, G G Sandor.   

Abstract

A rare complication of balloon atrial septostomy is presented in an infant with D-transposition of the great arteries (D-TGA) undergoing a Rashkind septostomy. The balloon could not be deflated after the first pass across the atrial septum because of a blocked catheter lumen. Deflation was achieved with a fine-gauge needle introduced percutaneously via a transhepatic approach. The management of nondeflatable balloons is reviewed.

Entities:  

Mesh:

Year:  1990        PMID: 2395743     DOI: 10.1007/BF02238846

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  11 in total

1.  Risks of needle biopsy of the liver.

Authors:  R TERRY
Journal:  Br Med J       Date:  1952-05-24

2.  Balloon deflation failure: a hazard of "medical" atrial septostomy.

Authors:  A R Hohn; H M Webb
Journal:  Am Heart J       Date:  1972-03       Impact factor: 4.749

3.  [Hazards of percutaneous liver biopsy].

Authors:  H Lindner
Journal:  Med Klin       Date:  1971-06-18

4.  Balloon embolization during atrial septostomy.

Authors:  J H Vogel
Journal:  Circulation       Date:  1970-07       Impact factor: 29.690

5.  Inability to deflate catheter balloon: a complication of balloon atrial septostomy.

Authors:  R C Ellison; W H Plauth; A B Gazzaniga; D C Fyler
Journal:  J Pediatr       Date:  1970-04       Impact factor: 4.406

6.  A new complication of Rashkind balloon septostomy.

Authors:  O Scott
Journal:  Arch Dis Child       Date:  1970-10       Impact factor: 3.791

7.  Arterial switch operation for transposition of the great arteries with intact ventricular septum.

Authors:  J E Mayer; R A Jonas; A R Castañeda
Journal:  J Card Surg       Date:  1986-06       Impact factor: 1.620

8.  Interatrial groove tear: an unusual complication of balloon atrial septostomy.

Authors:  W B Blanchard; D G Knauf; B E Victorica
Journal:  Pediatr Cardiol       Date:  1983 Apr-Jun       Impact factor: 1.655

9.  Balloon atrial septostomy under two dimensional echocardiographic control.

Authors:  L D Allan; R Leanage; R Wainwright; M C Joseph; M Tynan
Journal:  Br Heart J       Date:  1982-01

10.  Fatal over-distention of an atrioseptostomy catheter.

Authors:  H M Sondheimer; R E Kavey; M S Blackman
Journal:  Pediatr Cardiol       Date:  1982       Impact factor: 1.655

View more