Literature DB >> 23956723

Esophageal misplacement of a single-lumen tube after its exchange for a double-lumen tube despite the use of an airway-exchange catheter.

Sung Mi Hwang1, Jae Jun Lee, Ji Su Jang, Nak Hum Lee.   

Abstract

An airway-exchange catheter (AEC) can increase the safety of exchanges of endotracheal tubes (ETTs); however, the procedure is associated with potential risks. We describe a case of esophageal misplacement of a single-lumen ETT after switching from a double-lumen tube, despite the use of an AEC as a guidewire. To avoid this, physicians should consider the insertion depth and maintenance depth of the AEC and should verify its position before changing ETTs and should perform, if possible, with simultaneous visualization of the glottis with direct or video laryngoscopy during the exchange. Additionally, the new ETT position should be confirmed by auscultation, end-tidal carbon dioxide, and portable chest X-ray.

Entities:  

Keywords:  Airway extubation; esophagus; intratracheal; intubation

Year:  2013        PMID: 23956723      PMCID: PMC3737699          DOI: 10.4103/1658-354X.114050

Source DB:  PubMed          Journal:  Saudi J Anaesth


  9 in total

1.  Airway exchange catheters: simple concept, potentially great danger.

Authors:  J L Benumof
Journal:  Anesthesiology       Date:  1999-08       Impact factor: 7.892

2.  Facilitating submental endotracheal intubation with an endotracheal tube exchanger.

Authors:  P Drolet; M Girard; J Poirier; Y Grenier
Journal:  Anesth Analg       Date:  2000-01       Impact factor: 5.108

3.  Unforeseen esophageal misplacement of airway exchange catheter leading to gastric perforation.

Authors:  Douglas Fetterman; Anna Dubovoy; Michael Reay
Journal:  Anesthesiology       Date:  2006-05       Impact factor: 7.892

4.  Tracheal laceration after the use of an airway exchange catheter for double-lumen tube placement.

Authors:  Vinoo Thomas; Steven M Neustein
Journal:  J Cardiothorac Vasc Anesth       Date:  2006-11-30       Impact factor: 2.628

5.  A method of avoiding loss of airway control during tracheal tube change using an airway exchange catheter.

Authors:  Swaminathan Karthik; Balachundhar Subramaniam
Journal:  Anesth Analg       Date:  2007-10       Impact factor: 5.108

6.  Endotracheal tube exchangers: should we look for safer alternatives?

Authors:  Kassem Harris; Michel Chalhoub; Rabih Maroun; Dany Elsayegh
Journal:  Heart Lung       Date:  2011-08-10       Impact factor: 2.210

7.  The highlight technique: airway exchange catheters with a colored marking may improve safety of airway management.

Authors:  Stanley Leeson
Journal:  Anesth Analg       Date:  2011-02       Impact factor: 5.108

8.  A jet-stylet endotracheal catheter for difficult airway management.

Authors:  R C Bedger; J L Chang
Journal:  Anesthesiology       Date:  1987-02       Impact factor: 7.892

Review 9.  Management of the difficult adult airway. With special emphasis on awake tracheal intubation.

Authors:  J L Benumof
Journal:  Anesthesiology       Date:  1991-12       Impact factor: 7.892

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.