Literature DB >> 23954524

Comparison of the actual amount of axial movement of 3 aspheric intraocular lenses using anterior segment optical coherence tomography.

Youngsub Eom1, Su-Yeon Kang, Jong-Suk Song, Hyo Myung Kim.   

Abstract

PURPOSE: To compare the mean effective lens position (ELP) and actual amount of axial movement of 3 aspheric intraocular lenses (IOLs) using anterior segment optical coherence tomography (AS-OCT).
SETTING: Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea.
DESIGN: Retrospective comparative study.
METHODS: Consecutive patients had phacoemulsification with aspheric IOL implantation. The ELP measurements by AS-OCT were taken 1 week and 1, 3, and 6 months postoperatively. The ELPRMS was defined as the root mean square (RMS) of the change in ELP at each follow-up timepoint.
RESULTS: An XL Stabi ZO 3-plate IOL was implanted in 30 eyes, an Acrysof IQ C-loop IOL in 22 eyes, and an Akreos MI-60 4-plate IOL in 17 eyes. The 4-plate IOL showed significant changes in the mean ELP from 1 week to 1 month and from 3 to 6 months postoperatively (P=.005 and P=.028, respectively). The changes of the other 2 IOLs were insignificant during the 3 postoperative visits. However, the mean ELPRMS of the C-loop IOL (0.06 mm ± 0.31 [SD]) was smaller than that of the 3-plate IOL (0.14 ± 0.28 mm) and the 4-plate IOL (0.20 ± 0.35 mm) (P=.014 and P=.023, respectively) during the 3 timepoints.
CONCLUSION: An appropriate method based on the actual amount of axial IOL movement, such as the ELPRMS, is needed to assess the axial positional stability of IOLs. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23954524     DOI: 10.1016/j.jcrs.2013.04.040

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses.

Authors:  Jung Wan Kim; Youngsub Eom; Wonkyung Park; Jong Suk Song; Ji Won Jeong; Seh Kwang Park; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-05-28       Impact factor: 3.535

2.  Influences of anterior capsule polishing on effective lens position after cataract surgery: a randomized controlled trial.

Authors:  Yang Gao; Guang-Fu Dang; Xu Wang; Lian Duan; Xin-Yi Wu
Journal:  Int J Clin Exp Med       Date:  2015-08-15

3.  Influence of corneal power on intraocular lens power of the second eye in the SRK/T formula in bilateral cataract surgery.

Authors:  Young Choi; Youngsub Eom; Jong Suk Song; Hyo Myung Kim
Journal:  BMC Ophthalmol       Date:  2017-12-28       Impact factor: 2.209

4.  Anterior Chamber Depth Change Following Cataract Surgery in Pseudoexfoliation Syndrome; a Preliminary Study.

Authors:  Mohammad Reza Fallah Tafti; Hossein Abdollah Beiki; S Farzad Mohammadi; Golshan Latifi; Elham Ashrafi; Zahra Fallah Tafti
Journal:  J Ophthalmic Vis Res       Date:  2017 Apr-Jun

5.  Effects of Residual Anterior Lens Epithelial Cell Removal on Axial Position of Intraocular Lens after Cataract Surgery.

Authors:  Seung Pil Bang; Young-Sik Yoo; Jong Hwa Jun; Choun-Ki Joo
Journal:  J Ophthalmol       Date:  2018-08-19       Impact factor: 1.909

6.  Comparative evaluation of refractive outcomes after implantation of two types of intraocular lenses with different diopter intervals (0.25 diopter versus 0.50 diopter).

Authors:  Minjung Kim; Youngsub Eom; Jong Suk Song; Hyo Myung Kim
Journal:  BMC Ophthalmol       Date:  2018-07-18       Impact factor: 2.209

7.  Comparison of postoperative axial stability of intraocular lens and capsulotomy parameters between precision pulse capsulotomy and continuous curvilinear capsulotomy: A prospective cohort study.

Authors:  Seung Pil Bang; Jong Hwa Jun
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

8.  Comparison of two one-piece acrylic foldable intraocular lenses: Short-term change in axial movement after cataract surgery and its effect on refraction.

Authors:  So Goto; Naoyuki Maeda; Kazuhiko Ohnuma; Toru Noda
Journal:  PLoS One       Date:  2022-08-30       Impact factor: 3.752

9.  Axial elongation measured by long scan depth optical coherence tomography during pilocarpine-induced accommodation in intraocular lens-implanted eyes.

Authors:  Yilei Shao; Qiuruo Jiang; Di Hu; Lingmin Zhang; Meixiao Shen; Shenghai Huang; Lin Leng; Yimin Yuan; Qi Chen; Dexi Zhu; Jianhua Wang; Fan Lu
Journal:  Sci Rep       Date:  2018-01-31       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.