Literature DB >> 23954062

Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study.

Shahid Rahman1, Tara Leesar, Mehmet Cilingiroglu, Mohamed Effat, Imran Arif, Tarek Helmy, Massoud A Leesar.   

Abstract

OBJECTIVES: Intravascular ultrasound (IVUS) was performed to investigate the impact of kissing balloon inflation (KBI) on the main vessel (MV) stent volume, area, and symmetry after side-branch (SB) dilation in patients with coronary bifurcation lesions (CBL).
BACKGROUND: It remains controversial whether KBI would restore the MV stent area and symmetry loss after SB dilation.
METHODS: A total of 88 serial IVUS examinations of the MV were performed after MV angioplasty, MV stenting, SB dilation, and KBI in 22 patients with CBL. The MV stent was divided into proximal, bifurcation, and distal segments; the stent volume index (SVI), minimal stent area (MSA), stent symmetry index (SSI), and external elastic membrane (EEM) volume index were measured in 198 stent segments and compared after MV stenting, SB dilation, and KBI.
RESULTS: In the bifurcation segment, SVI, MSA, and SSI were significantly smaller after SB dilation than after MV stenting and KBI (SVI was 6.10 ± 1.50 mm(3)/mm vs. 6.68 ± 1.60 mm(3)/mm and 6.57 ± 1.60 mm(3)/mm, respectively, p < 0.05; MSA was 5.15 ± 1.30 mm(2) vs. 6.08 ± 1.40 mm(2) and 5.86 ± 1.50 mm(2), respectively, p < 0.05; and SSI was 0.78 ± 0.02 mm(2) vs. 0.87 ± 0.03 mm(2) and 0.84 ± 0.03 mm(2), respectively, p < 0.05). KBI restored the MV SVI, MSA, and SSI after SB dilation. In the proximal segment, SVI, MSA, and EEM volume index were significantly larger, but SSI was smaller after KBI than after MV stenting and SB dilation. In the distal segment, neither SB dilation nor KBI had a significant impact on the MV stent volume or symmetry.
CONCLUSIONS: This is the first comprehensive volumetric IVUS analysis of CBL, to our knowledge, demonstrating that KBI restores the MV stent volume, area, and symmetry loss after SB dilation in the bifurcation segment, and induces asymmetric stent expansion in the proximal segment.
Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CBL; DES; EEM; EES; ISA; IVUS; KBI; MLD; MSA; MV; P&M; PCI; POT; QCA; RD; SB; SES; SSI; SVI; bifurcation lesions; coronary bifurcation lesions; drug-eluting stent(s); everolimus-eluting stent(s); external elastic membrane; incomplete stent apposition; intravascular ultrasound; kissing balloon inflation; kissing balloon inflation(s); main vessel; minimal lumen diameter; minimal stent area; percutaneous coronary intervention; plaque plus media; proximal optimization treatment; quantitative coronary angiography; reference diameter; side branch; sirolimus-eluting stent(s); stent symmetry index; stent volume index; stenting

Mesh:

Year:  2013        PMID: 23954062     DOI: 10.1016/j.jcin.2013.04.019

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  11 in total

1.  The impact of three-dimensional optical coherence tomography and kissing-balloon inflation for stent implantation to bifurcation lesions.

Authors:  Hiroshi Koiwaya; Masao Takemoto; Kenji Ogata; Tatsuya Nakama; Makoto Furugen; Nozomi Watanabe; Nehiro Kuriyama; Yoshisato Shibata
Journal:  J Cardiol Cases       Date:  2016-01-16

2.  Final kissing balloon inflation for coronary bifurcation lesions treated with single-stent technique : A meta-analysis.

Authors:  G Liu; X Ke; Z-B Huang; L-C Wang; Z-N Huang; Y Guo; M Long; X-X Liao
Journal:  Herz       Date:  2017-11-27       Impact factor: 1.443

Review 3.  Stenting of coronary bifurcation lesions: a literature and technical review.

Authors:  Joo Myung Lee; Kyung Woo Park; Bon-Kwon Koo; Hyo-Soo Kim
Journal:  Curr Cardiol Rep       Date:  2015-06       Impact factor: 2.931

4.  Intravascular ultrasound-guided drug-eluting stent implantation is associated with improved clinical outcomes in patients with unstable angina and complex coronary artery true bifurcation lesions.

Authors:  Liang Chen; Tian Xu; Xian-Jun Xue; Jun-Jie Zhang; Fei Ye; Nai-Liang Tian; Shao-Liang Chen
Journal:  Int J Cardiovasc Imaging       Date:  2018-07-06       Impact factor: 2.357

5.  Double kissing inflation outside the stent secures the patency of small side branch without rewiring.

Authors:  Hongbo Yang; Yanan Song; Jiatian Cao; Xueyi Weng; Feng Zhang; Yuxiang Dai; Hao Lu; Chenguang Li; Zheyong Huang; Juying Qian; Junbo Ge
Journal:  BMC Cardiovasc Disord       Date:  2021-05-07       Impact factor: 2.298

6.  Clinical Outcome of Double Kissing Crush Versus Provisional Stenting of Coronary Artery Bifurcation Lesions: The 5-Year Follow-Up Results From a Randomized and Multicenter DKCRUSH-II Study (Randomized Study on Double Kissing Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions).

Authors:  Shao-Liang Chen; Teguh Santoso; Jun-Jie Zhang; Fei Ye; Ya-Wei Xu; Qiang Fu; Jing Kan; Feng-Fu Zhang; Yong Zhou; Du-Jiang Xie; Tak W Kwan
Journal:  Circ Cardiovasc Interv       Date:  2017-02       Impact factor: 6.546

7.  Innominate artery bifurcation pseudoaneurysm repair by "kissing stent-grafts technique": a case report.

Authors:  Xin Li; Chang Shu; Quan Ming Li; Kun Fang; Ming Li; Wenwu Cai
Journal:  J Med Case Rep       Date:  2018-11-27

8.  Modified balloon-stent kissing technique avoid side-branch compromise for simple true bifurcation lesions.

Authors:  Wen-Bo Qu; Wei Zhang; Jun-Yan Liu; Fan Zhang; Shuai-Nan Mu; Sheng-Ming Zhang; Hao Tang; Xi-Qian Liu; Xue-Qi Li; Bing-Chen Liu
Journal:  BMC Cardiovasc Disord       Date:  2019-04-08       Impact factor: 2.298

9.  Comparative Computed Flow Dynamic Analysis of Different Optimization Techniques in Left Main Either Provisional or Culotte Stenting.

Authors:  Gianluca Rigatelli; Fabio Dell'Avvocata; Marco Zuin; Sara Giatti; Khanh Duong; Trung Pham; Nguyen Si Tuan; Dobrin Vassiliev; Ramesh Daggubati; Thach Nguyen
Journal:  J Transl Int Med       Date:  2017-12-29

Review 10.  Efficacy of coronary imaging on bifurcation intervention.

Authors:  Kensuke Takagi; Ryoji Nagoshi; Byeong-Keuk Kim; Woong Kim; Yoshihisa Kinoshita; Junya Shite; Yutaka Hikichi; Young Bin Song; Chang-Wook Nam; Bon-Kwon Koo; Soo-Joong Kim; Yoshinobu Murasato
Journal:  Cardiovasc Interv Ther       Date:  2020-09-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.