Literature DB >> 23949357

Hyoid expansion with titanium plate and screw: a human cadaveric study using computer-assisted airway measurement.

Song-Tar Toh1, Pon-Poh Hsu, Kah Leong Alvin Tan, Kuo-Sun Peter Lu, Hong-Juan Han.   

Abstract

IMPORTANCE: Hyoid expansion with suspension can potentially increase the upper airway at the hypopharyngeal level, benefitting patients with sleep-related breathing disorder.
OBJECTIVES: To document the effect of hyoid expansion using titanium plate and screw on retrolingual hypopharyngeal airway dimension and to compare the airway dimension after isolated hyoid expansion with hyoid expansion + hyomandibular suspension.
DESIGN: Anatomical cadaveric dissection study.
SETTING: This study was performed in a laboratory setting using human cadavers. INTERVENTION: This is an anatomical feasibility study of hyoid expansion using titanium plate and screw on 10 cadaveric human heads and necks. The hyoid bone is trifractured with bony cuts made just medial to the lesser cornu. The freed hyoid body and lateral segments are expanded and stabilized to a titanium adaptation plate. Computer-assisted airway measurement (CAM) was used to measure the airway dimension at the hypopharynx at the level of the tongue base before and after the hyoid expansion. The expanded hyoid bone was then suspended to the mandible, and the airway dimension was measured again with CAM. MAIN OUTCOMES AND MEASURES: Airway dimension after isolated hyoid expansion with hyoid expansion with hyomandibular suspension. RESULTS Hyoid expansion with titanium plate and screw resulted in statistical significant increase in the retrolingual hypopharyngeal airway space in all of the 10 human cadavers. The mean (SD) increase in retroglossal area was 33.4 (13.2) mm² (P < .005) (range, 6.0-58.7 mm²). Hyoid expansion with hyomandibular suspension resulted in a greater degree of airway enlargement. The mean (SD) increase in retroglossal area was 99.4 (15.0) mm² (P < .005) (range, 81.9-127.5 mm²). CONCLUSIONS AND RELEVANCE: The retrolingual hypopharyngeal airway space increased with hyoid expansion using titanium plate and screw in our human cadaveric study, measured using CAM. The degree of increase is further augmented with hyomandibular suspension.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23949357     DOI: 10.1001/jamaoto.2013.3906

Source DB:  PubMed          Journal:  JAMA Otolaryngol Head Neck Surg        ISSN: 2168-6181            Impact factor:   6.223


  2 in total

1.  The dimension of hyoid bone is independently associated with the severity of obstructive sleep apnea.

Authors:  Jong Gyun Ha; Hyun Jin Min; Sang Hyeon Ahn; Chang-Hoon Kim; Joo-Heon Yoon; Jeung-Gweon Lee; Hyung-Ju Cho
Journal:  PLoS One       Date:  2013-12-02       Impact factor: 3.240

2.  Hyoid expansion with titanium plate and screws with hyomandibular suspension: A study on human cadavers with computed tomographic comparative analysis.

Authors:  Adele Chin Wei Ng; Parag Ratnakar Salkade; Mahalakshmi Rangabashyam; Shaun Ray Han Loh; Song Tar Toh
Journal:  Laryngoscope Investig Otolaryngol       Date:  2020-10-21