Literature DB >> 23949235

Bioimpedance-guided fluid management in hemodialysis patients.

Ulrich Moissl1, Marta Arias-Guillén, Peter Wabel, Néstor Fontseré, Montserrat Carrera, José Maria Campistol, Francisco Maduell.   

Abstract

BACKGROUND AND OBJECTIVES: Achieving and maintaining optimal fluid status remains a major challenge in hemodialysis therapy. The aim of this interventional study was to assess the feasibility and clinical consequences of active fluid management guided by bioimpedance spectroscopy in chronic hemodialysis patients. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Fluid status was optimized prospectively in 55 chronic hemodialysis patients over 3 months (November 2011 to February 2012). Predialysis fluid overload was measured weekly using the Fresenius Body Composition Monitor. Time-averaged fluid overload was calculated as the average between pre- and postdialysis fluid overload. The study aimed to bring the time-averaged fluid overload of all patients into a target range of 0.5 ± 0.75 L within the first month and maintain optimal fluid status until study end. Postweight was adjusted weekly according to a predefined protocol.
RESULTS: Time-averaged fluid overload in the complete study cohort was 0.9 ± 1.6 L at baseline and 0.6 ± 1.1 L at study end. Time-averaged fluid overload decreased by -1.20 ± 1.32 L (P<0.01) in the fluid-overloaded group (n=17), remained unchanged in the normovolemic group (n=26, P=0.59), and increased by 0.59 ± 0.76 L (P=0.02) in the dehydrated group (n=12). Every 1 L change in fluid overload was accompanied by a 9.9 mmHg/L change in predialysis systolic BP (r=0.55, P<0.001). At study end, 76% of all patients were either on time-averaged fluid overload target or at least closer to target than at study start. The number of intradialytic symptoms did not change significantly in any of the subgroups.
CONCLUSIONS: Active fluid management guided by bioimpedance spectroscopy was associated with an improvement in overall fluid status and BP.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23949235      PMCID: PMC3805085          DOI: 10.2215/CJN.12411212

Source DB:  PubMed          Journal:  Clin J Am Soc Nephrol        ISSN: 1555-9041            Impact factor:   8.237


  16 in total

1.  Body fluid volume determination via body composition spectroscopy in health and disease.

Authors:  Ulrich M Moissl; Peter Wabel; Paul W Chamney; Ingvar Bosaeus; Nathan W Levin; Anja Bosy-Westphal; Oliver Korth; Manfred J Müller; Lars Ellegård; Vibeke Malmros; Charoen Kaitwatcharachai; Martin K Kuhlmann; Fansan Zhu; Nigel J Fuller
Journal:  Physiol Meas       Date:  2006-07-25       Impact factor: 2.833

2.  Importance of whole-body bioimpedance spectroscopy for the management of fluid balance.

Authors:  Peter Wabel; Paul Chamney; Ulrich Moissl; Tomas Jirka
Journal:  Blood Purif       Date:  2009-01-23       Impact factor: 2.614

3.  Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial.

Authors:  Ender Hur; Mehmet Usta; Huseyin Toz; Gulay Asci; Peter Wabel; Serdar Kahvecioglu; Meral Kayikcioglu; Meltem Sezis Demirci; Mehmet Ozkahya; Soner Duman; Ercan Ok
Journal:  Am J Kidney Dis       Date:  2013-02-15       Impact factor: 8.860

4.  Randomized trial of bioelectrical impedance analysis versus clinical criteria for guiding ultrafiltration in hemodialysis patients: effects on blood pressure, hydration status, and arterial stiffness.

Authors:  Mihai Onofriescu; Nicoleta Genoveva Mardare; Liviu Segall; Luminiţa Voroneanu; Claudiu Cuşai; Simona Hogaş; Serban Ardeleanu; Ionuţ Nistor; Octavian Viorel Prisadă; Radu Sascău; Adrian Covic
Journal:  Int Urol Nephrol       Date:  2011-06-19       Impact factor: 2.370

5.  Volume control in peritoneal dialysis patients guided by bioimpedance spectroscopy assessment.

Authors:  Ya-Jun Luo; Xin-Hong Lu; Feidhlim Woods; Tao Wang
Journal:  Blood Purif       Date:  2011-01-14       Impact factor: 2.614

6.  Importance of normohydration for the long-term survival of haemodialysis patients.

Authors:  Charles Chazot; Peter Wabel; Paul Chamney; Ulrich Moissl; Sebastian Wieskotten; Volker Wizemann
Journal:  Nephrol Dial Transplant       Date:  2012-01-17       Impact factor: 5.992

7.  Fluid retention is associated with cardiovascular mortality in patients undergoing long-term hemodialysis.

Authors:  Kamyar Kalantar-Zadeh; Deborah L Regidor; Csaba P Kovesdy; David Van Wyck; Suphamai Bunnapradist; Tamara B Horwich; Gregg C Fonarow
Journal:  Circulation       Date:  2009-01-26       Impact factor: 29.690

8.  Dry-weight reduction in hypertensive hemodialysis patients (DRIP): a randomized, controlled trial.

Authors:  Rajiv Agarwal; Pooneh Alborzi; Sangeetha Satyan; Robert P Light
Journal:  Hypertension       Date:  2009-01-19       Impact factor: 10.190

9.  The mortality risk of overhydration in haemodialysis patients.

Authors:  Volker Wizemann; Peter Wabel; Paul Chamney; Wojciech Zaluska; Ulrich Moissl; Christiane Rode; Teresa Malecka-Masalska; Daniele Marcelli
Journal:  Nephrol Dial Transplant       Date:  2009-01-07       Impact factor: 5.992

10.  Guided optimization of fluid status in haemodialysis patients.

Authors:  Petr Machek; Tomas Jirka; Ulrich Moissl; Paul Chamney; Peter Wabel
Journal:  Nephrol Dial Transplant       Date:  2009-09-30       Impact factor: 5.992

View more
  46 in total

1.  Bioimpedance analysis versus lung ultrasonography for optimal risk prediction in hemodialysis patients.

Authors:  Dimitrie Siriopol; Luminita Voroneanu; Simona Hogas; Mugurel Apetrii; Angelica Gramaticu; Raluca Dumea; Alexandru Burlacu; Radu Sascau; Mehmet Kanbay; Adrian Covic
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-01       Impact factor: 2.357

2.  Time to improve fluid management in hemodialysis: should we abandon clinical assessment and routinely use bioimpedance?

Authors:  Adrian Covic; Mihai Onofriescu
Journal:  Clin J Am Soc Nephrol       Date:  2013-08-15       Impact factor: 8.237

Review 3.  Body composition during growth in children: limitations and perspectives of bioelectrical impedance analysis.

Authors:  U G Kyle; C P Earthman; C Pichard; J A Coss-Bu
Journal:  Eur J Clin Nutr       Date:  2015-06-03       Impact factor: 4.016

Review 4.  The relationship of volume overload and its control to hypertension in hemodialysis patients.

Authors:  Jennifer E Flythe; Nisha Bansal
Journal:  Semin Dial       Date:  2019-09-29       Impact factor: 3.455

5.  Application of bioimpedance spectroscopy in Asian dialysis patients (ABISAD-III): a randomized controlled trial for clinical outcomes.

Authors:  Chen Huan-Sheng; Chang Yeong-Chang; Hsieh Ming-Hsing; Tseng Fan-Lieh; Lin Chu-Cheng; Wu Tsai-Kun; Chen Hung-Ping; Hung Sze-Hung; Chiu Hsien-Chang; Lee Chia-Chen; Hou Chun-Cheng; Cheng Chun-Ting; Liou Hung-Hsiang; Lin Chun-Ju; Lim Paik-Seong
Journal:  Int Urol Nephrol       Date:  2016-09-12       Impact factor: 2.370

6.  Bioimpedance spectroscopy method to determine hypervolemia in maintenance hemodialysis patients.

Authors:  O Merhametsiz; E G Oguz; O Yayar; B Bektan; B Canbakan; D Ayli
Journal:  Hippokratia       Date:  2015 Oct-Dec       Impact factor: 0.471

7.  Excess volume removal following lung ultrasound evaluation decreases central blood pressure and pulse wave velocity in hemodialysis patients: a LUST sub-study.

Authors:  Charalampos Loutradis; Aikaterini Papagianni; Robert Ekart; Marieta Theodorakopoulou; Ioanna Minopoulou; Efstathios Pagourelias; Stella Douma; Asterios Karagiannis; Francesca Mallamaci; Carmine Zoccali; Gerard London; Pantelis A Sarafidis
Journal:  J Nephrol       Date:  2020-05-23       Impact factor: 3.902

Review 8.  Evaluation and Treatment of Hypertension in End-Stage Renal Disease Patients on Hemodialysis.

Authors:  Peter Noel Van Buren
Journal:  Curr Cardiol Rep       Date:  2016-12       Impact factor: 2.931

9.  Bedside sonographic assessments for predicting predialysis fluid overload in children with end-stage kidney disease.

Authors:  Ahmet Yontem; Cagla Cagli; Dincer Yildizdas; Ozden Ozgur Horoz; Faruk Ekinci; Bahriye Atmis; Aysun Karabay Bayazit
Journal:  Eur J Pediatr       Date:  2021-04-30       Impact factor: 3.183

Review 10.  Using Bioimpedance Spectroscopy to Assess Volume Status in Dialysis Patients.

Authors:  Frank M van der Sande; Esther R van de Wal-Visscher; Stefano Stuard; Ulrich Moissl; Jeroen P Kooman
Journal:  Blood Purif       Date:  2019-12-18       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.